Skip to main content
Generator JERBINDO CJPS C-113 WP
Diesel Generator Set | Cummins

JERBINDO CJPS C-113 WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO CJPS C-113 WP — Open Frame
Generator JERBINDO CJPS C-113 WP — Silent
Generator JERBINDO CJPS C-113 WP — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
113 kVA
90 kW
Standby Power
124.3 kVA
99 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
20 L/hr

JERBINDO CJPS C-113 WP is a diesel generator rated at 113 kVA prime and 124.3 kVA standby, powered by a water-cooled Cummins 6BTA5.9G2 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Hospital
  • Hotel
  • Office Tower

Engine System

Cooling SystemWater Cooled
Engine BrandCummins
Engine Model6BTA5.9G2

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement6 in-line
Cylinders6
Displacement5.9 L
Bore102 mm
Stroke120 mm
GovernorElectronic
Max Engine Power116 kWm
Oil Capacity16.4 L

Alternator

Brand & ModelStamford UCI274D
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output113 kVA | 90 kW
Standby Output124.3 kVA | 99 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)2150 x 1030 x 1580 mm3600 x 1200 x 2300 mm
Dry Weight1400 kg1820 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load27 L/hr
  • 75% Typical Load20 L/hr
  • 50% Light Load14 L/hr

Tank capacity: 150 L

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 20 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO CJPS C-113 WP best?

This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 113 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 113 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 124.3 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-125 WP Open Type — Open Frame
Generator JERBINDO CJPS C-125 WP Open Type — Silent
Generator JERBINDO CJPS C-125 WP Open Type — Silent Mobile
JERBINDO

CJPS C-125 WP

Engine: Cummins 6BTAA5.9G2

Prime
125 kVA
Standby
137.5 kVA
Alternator
Stamford UCI274E
Cooling
Water Cooled
Fuel @ 75%
23 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-100 WP Open Type — Open Frame
Generator JERBINDO CJPS C-100 WP Open Type — Silent
Generator JERBINDO CJPS C-100 WP Open Type — Silent Mobile
JERBINDO

CJPS C-100 WP

Engine: Cummins 6BT5.9-G2

Prime
100 kVA
Standby
110 kVA
Alternator
Stamford UCI274 C
Cooling
Water Cooled
Fuel @ 75%
17 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS O-100 WP Open Type — Open Frame
Generator JERBINDO CJPS O-100 WP Open Type — Silent
Generator JERBINDO CJPS O-100 WP Open Type — Silent Mobile
JERBINDO

CJPS O-100 WP

Engine: Cummins QSB5-G5

Prime
100 kVA
Standby
110 kVA
Alternator
Stamford UCI274 C
Cooling
Water Cooled
Fuel @ 75%
20 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO BJPS-100-WP Open Type — Open Frame
Generator JERBINDO BJPS-100-WP Open Type — Silent
Generator JERBINDO BJPS-100-WP Open Type — Silent Mobile
JERBINDO

BJPS-100-WP

Engine: Baudouin 4M10G110/5

Prime
100 kVA
Standby
110 kVA
Alternator
Leroy Somer TAL A44 D
Cooling
Water Cooled

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.