
Open Type Diesel Generators
JERBINDO open-type diesel generators from 12 to 4125 kVA for generator rooms and industrial sites. Every JERBINDO generator is built open; a silent canopy is optional.
Open type = a generator without a canopy, installed in a dedicated generator room. Need a sound-attenuated canopy? See Silent Type →
Open Type Generator Options
Open-type generator manufacturer since 1977. Every JERBINDO model from 12 kVA to 4125 kVA is available as open type, with Perkins, Cummins, Mitsubishi, Deutz and Baudouin engines.
JERBINDO Power Systems
Integrated power generation systems, from industrial diesel generators and electrical panels to systems customized for the requirements of each project.
VOLTRAGEN
15–60 kVA silent generators for clinics, shops, restaurants, hotels, schools, offices, and homes, keeping operations running when the power goes out.
OEM for Global Engine Brands
Appointed as Original Equipment Manufacturer for Cummins G-Drive, DEUTZ, Mitsubishi Heavy Industries, and Baudouin PowerKit.
TKDN & e-Catalogue
JERBINDO and VOLTRAGEN products are TKDN certified and listed on the e-Catalogue for government projects.

Powered by
Open Type, the Base of Every Generator
An open-type generator has no canopy: engine, alternator and panel sit on a base frame. Every JERBINDO generator is built open; a silent canopy or container is an option depending on where it is installed.
Best suited for
- Building generator rooms
- Factories & industry
- Power plants & utilities
- Mines (generator house)
- Data centers
- Large projects

Advantages
Easy maintenance access
Every component is exposed, so inspection and service are quicker.
Better cooling
Better airflow suits heavy and prime duty.
More economical
No canopy cost, ideal where a soundproof generator room exists.
Flexible
A silent canopy or container can be added later.
Comparing Silent Type and Open Type
Choose a generator type by installation site, noise limits and whether a generator room is available.
| Aspect | Silent Type | Open TypeThis page |
|---|---|---|
| Canopy | Silent TypeSound-attenuated, weatherproof canopy | Open TypeNo canopy; the set sits on a base frame |
| Noise | Silent TypeLower, thanks to insulation and a silencer | Open TypeHigher; needs a sound-treated generator room |
| Installation site | Silent TypeOutdoors or open areas, no dedicated generator room | Open TypeDedicated generator room or generator house |
| Weather protection | Silent TypeProtected from rain, heat and dust | Open TypeDepends on the generator room |
| Maintenance access | Silent TypeThrough the canopy's service doors | Open TypeEvery component exposed for faster inspection |
| Size & weight | Silent TypeLarger and heavier because of the canopy | Open TypeMore compact at the same capacity |
| Unit cost | Silent TypeHigher, as the canopy is included | Open TypeMore economical when a generator room exists |
Your One-Stop Generator Solution
We provide more than generators, supporting installation, testing, and maintenance to help keep your generator running reliably.

Installation
Generator-set installation, ATS/AMF panel, commissioning, system synchronization, electrical integration, and testing.

Maintenance
Preventive maintenance, routine inspections, performance testing, oil and filter replacement, component checks, and ongoing maintenance.

Service & Spare Parts
Troubleshooting, repairs, spare parts replacement, overhauls, engine and alternator repairs, and performance restoration.
Open Type Generator Projects Across Various Sectors
We have completed a wide range of open type generator projects to support power needs across different locations and operating conditions.

Power & Utilities
Niigata 2 x 6250 kVA Open Type
South Minahasa, North Sulawesi

Water Utilities
Baudouin 1000 & 1250 kVA Open Type
Semarang, Central Java

Retail & Trade
Kohler 5 x 2000 kVA Open Type
Surabaya, East Java

Hospitals, Clinics, Laboratories & Other Healthcare Facilities
Deutz 2 x 500 kVA Open Type
Cilacap, Central Java

Power & Utilities
Cummins 2 x 2000 kVA Open Type
Palembang, South Sumatra

Data Centers
Kohler 4 x 2500 kVA Open Type
Bandung, West Java

Power & Utilities
Baudouin 2 x 1750 kVA Open Type
Sulawesi

Educational Institutions
Baudouin 2 x 2000 kVA Open Type
Central Jakarta, Jakarta

Office & Commercial Buildings
Generator Installation
Kulon Progo, Yogyakarta

Office & Commercial Buildings
Perkins 3 x 1000 kVA Open Type
Surabaya, East Java
Frequently Asked Questions
What is the difference between open and silent generators?
An open generator has no canopy and goes in a generator room; a silent generator has a sound-attenuated, weatherproof canopy for outdoor sites. Every JERBINDO generator is built open, with a silent canopy as an option.
What open-type capacities are available?
Every JERBINDO model from 12 kVA to 4125 kVA is available as open type.
What does an open type generator installation need?
A generator room with enough ventilation, a foundation, sound attenuation if needed, and exhaust and fuel routing.
Can an open type generator be converted to silent type?
Yes. A silent canopy can be added to suit the model and site.

Trusted by Various Companies
Decades of experience and a portfolio of projects across many sectors reflect our commitment to quality.
Our clients
Explore More Generator Solutions

Find the Right Industrial Generator Solution
Discuss your power requirements with our sales and service team to get the right products and services.








































