150 kVA Generator

Equal to 120 kW. Baudouin, Cummins & Perkins engines, open and silent, with fuel use and dimensions compared.

View Catalogue
Overview

Getting to Know 150 kVA Generators

A 150 kVA generator is about 120 kW at a power factor of 0.8. This capacity is common for office buildings, schools, clinics and small hotels that need backup for most of their load.

Several engine brands are available in the 150 kVA class, so fuel use and dimensions can be compared directly in the table.

Suited to

  • Office buildings
  • Schools & campuses
  • Clinics
  • Small hotels
  • Small factories
  • Cold storage

Prime or Standby?

Main power

150 kVA prime

3models
  • The generator is the main power source, for example at a site without grid power
  • It runs long hours every day with a varying load

e.g. BJPS-150-WP

Grid backup

150 kVA standby

3models
  • The generator only runs during grid outages
  • Prime slightly below 150 kVA, standby around 150 kVA: usually more economical

e.g. BJPS-135-WP

Model

150 kVA Generator Options

Every JERBINDO 150 kVA model by engine brand. Select a model for full specifications.

Baudouin engine

Fuel at 75% (prime): 24 L/hr2 models
ModelPrime kVAStandby kVA
BJPS-150-WP6M11G165/5150 kVA prime150165
BJPS-135-WP6M11G150/5150 kVA standby135150
Baudouin Generator

Cummins engine

Fuel at 75% (prime): 26 L/hr2 models
ModelPrime kVAStandby kVA
CJPS C-150 WP6BTAA5.9-G12150 kVA prime150165
CJPS O-135 WPQSB5-G6150 kVA standby135148.5
Cummins Generator

Perkins engine

Fuel at 75% (prime): 24.7 L/hr2 models
ModelPrime kVAStandby kVA
PJPS-150 WP1106A-70TAG2150 kVA prime150165
PJPS-135 WP1106A-70TG1150 kVA standby135148.5
Perkins Generator
Installation

Generator Room Requirements

General guidance for the 150 kVA class from engine and generator makers' installation manuals. Final figures follow the installation drawings and datasheet of the chosen unit.

Minimum room, 1 unit
5.6 × 4.0 m
Open type (L × W × H)
2300–2600 × 750–1000 × 1433–1570 mm
Silent canopy (L × W × H)
3400–3600 × 1200 × 2026–2300 mm

Service clearance

1.5 m per side

  • Leave at least about 1.5 m of clear space on every side of the generator for maintenance (Cummins' guide for units from 100 kVA; other sources give 0.9–1.2 m), plus room above it to open panels. With the largest open unit in this class, one generator needs a room of at least about 5.6 × 4.0 m.

Ventilation

Outlet ≈ 1.5× radiator

  • Provide an air inlet behind the generator and an outlet in front of the radiator. As a general guide, the outlet is about 1.5× the radiator core area and the inlet 1.5–2× (louvres cut the free area by about 25%). Keep the room no more than about 7–10 °C above outdoor air; above 40 °C the generator needs derating.
  • In this class the radiator fan is usually enough, as long as the openings are not blocked.

Foundation

≥ 2× unit weight

  • A concrete foundation of at least about 2× the generator's weight, extending 150–300 mm beyond the skid on every side, with vibration isolators between the skid and the foundation. Let the concrete cure for 28 days before loading. Dry weight of the open units in this class: 1.1–1.5 tonnes.

Day tank

190–210 L / 8 hours

  • Fuel use at 75% load: 24–26 L/hr, or about 190–210 L for 8 hours of running. Size the day tank from this; for longer running add a bulk tank with a transfer pump.
  • NFPA 37 limits a tank inside the generator room to 2,500 L unless it has its own fire-rated room; local regulations also apply.

Exhaust

Backpressure ≤ datasheet

  • A flexible connector at the engine outlet; pipework supported on its own so it does not load the engine, insulated and fitted with a rain cap. Choose the pipe and silencer so backpressure stays within the engine datasheet limit; avoid long runs and many bends. Discharge away from the air inlet.

Configuration

Open · Silent · Mobile

  • Open units for a generator room; silent canopy units for outdoors or noise-restricted surroundings.
  • An ATS/AMF panel is common for grid backup.
Projects

Generator Projects Around 150 kVA

Projects from our project list with units of around 150 kVA.

26 projects with units of around 150 kVA in our 2021–2026 project list. Client names are not shown.

  • Baudouin 150 kVA

    Government office

    Kediri, East Java · 2026

  • Perkins 150 kVA

    University

    Trenggalek, East Java · 2026

  • Cummins 150 kVA

    Hotel & resort

    Semarang, Central Java · 2026

  • Baudouin 150 kVA

    Factory

    Sampang, East Java · 2026

  • Cummins 150 kVA

    Office building

    Jakarta · 2025

  • Cummins 150 kVA

    Mining & smelter

    East Kalimantan · 2025

  • Baudouin 150 kVA

    Substation & power grid

    Bandung, West Java · 2025

  • Cummins 150 kVA

    Retail & commercial

    Pasuruan, East Java · 2025

FAQ

Frequently Asked Questions

How much does a 150 kVA generator cost?

The price of a 150 kVA generator depends on the engine brand, the configuration (open type, silent canopy, silent mobile), an ATS/AMF or synchronizing panel, installation and commissioning, the delivery location, and the warranty and after-sales service. Use Request a Quote with your requirements and our sales team will send a quotation. What shapes a generator price

How many kW is a 150 kVA generator?

At the 0.8 power factor commonly used for generators, 150 kVA equals 120 kW. The exact kW of each model is on its specification page.

How much diesel does a 150 kVA generator use?

At 75% load, the 150 kVA prime generators in our catalogue use about 24–26 L/hr, depending on the engine brand and model. Fuel use at 50% and 100% load is on each model's page.

Should I choose 150 kVA prime or standby?

Choose a 150 kVA prime model if the generator is the main power source or runs long hours with a varying load. If you need 150 kVA only as backup during grid outages, a model with a 150 kVA standby rating (and a slightly lower prime rating) is usually enough and more economical.

Conductorjasa industrial generator distribution for power projects across Indonesia
By the Numbers

Trusted by Various Companies

Decades of experience and a portfolio of projects across many sectors reflect our commitment to quality.

Our clients

  • Otsuka
  • BCA
  • Santos Jaya Abadi
  • Bank Indonesia
  • Telkom Indonesia
  • Adhi Karya
  • IKEA
  • JW Marriott
  • Spazio
  • Universitas Brawijaya
  • PUPR
  • Siloam Hospitals
  • Djarum
  • Avian Brands
  • PLN
  • Waskita
  • KAI
  • Ciputra World
  • Hero
  • Golden Palace Hotel
  • Institut Teknologi Bandung
  • Universitas Negeri Surabaya
  • Pemerintah Kota Mataram
  • Kievit
  • Gudang Garam
  • Polygon
  • Pertamina Geothermal Energy
  • WIKA
  • INKA
  • Giant
  • Ibis Hotel
  • Universitas Gadjah Mada
  • Universitas Ciputra
  • Pemerintah Kota Surabaya
  • Huawei
  • MNC
  • Kapal Api
  • PGN
  • PP Properti
  • Bulog
  • Transmart
  • Vasa Hotel
  • Westown View
  • Universitas Airlangga
  • Kementerian Sosial
  • National Hospital
Conductorjasa generator assembly workshop in Surabaya
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.