300 kVA Generator

Equal to 240 kW. Cummins, Perkins & Deutz engines, open and silent, with fuel use and dimensions compared.

View Catalogue
Overview

Getting to Know 300 kVA Generators

A 300 kVA generator is about 240 kW at a power factor of 0.8. It suits multi-storey buildings, hotels, hospitals and factories with mid-size motor loads.

For loads with many motors, account for starting current when choosing the capacity; the power calculator can give a first estimate.

Suited to

  • Multi-storey buildings
  • Hotels
  • Hospitals
  • Factories
  • Apartments
  • Shopping centres

Prime or Standby?

Main power

300 kVA prime

6models
  • The generator is the main power source, for example at a site without grid power
  • It runs long hours every day with a varying load

e.g. CJPS C-300 WP (CCEC)

Grid backup

300 kVA standby

3models
  • The generator only runs during grid outages
  • Prime slightly below 300 kVA, standby around 300 kVA: usually more economical

e.g. CJPS C-275 WP1

Model

300 kVA Generator Options

Every JERBINDO 300 kVA model by engine brand. Select a model for full specifications.

Cummins engine

Fuel at 75% (prime): 44–56 L/hr6 models
ModelPrime kVAStandby kVA
CJPS C-300 WP (CCEC)NTA855-G1A300 kVA prime300330
CJPS C-300 WP (DCEC)6LTAA9.5-G1300 kVA prime300330
CJPS O-300 WPQSL9-G7300 kVA prime300330
CJPS C-275 WP16LTAA9.5-G3300 kVA standby275302.5
CJPS C-275 WP2NTA855.G1A300 kVA standby275302.5
CJPS O-275 WPQSL9-G4300 kVA standby275302.5
Cummins Generator

Perkins engine

Fuel at 75% (prime): 45–48 L/hr2 models
ModelPrime kVAStandby kVA
PJPS-275 WP1506A-E88TAG4300 kVA prime300330
PJPS-300 WP1706A-E93TAG1 L300 kVA prime300330
Perkins Generator

Deutz engine

Fuel at 75% (prime): 51.7 L/hr1 models
ModelPrime kVAStandby kVA
DJPS-300 WPBF6M 1015 C300 kVA prime300330
Deutz Generator
Installation

Generator Room Requirements

General guidance for the 300 kVA class from engine and generator makers' installation manuals. Final figures follow the installation drawings and datasheet of the chosen unit.

Minimum room, 1 unit
6.2 × 4.4 m
Open type (L × W × H)
2800–3115 × 1100–1381 × 1700–2100 mm
Silent canopy (L × W × H)
4000–4400 × 1400–1650 × 2300–2660 mm

Service clearance

1.5 m per side

  • Leave at least about 1.5 m of clear space on every side of the generator for maintenance (Cummins' guide for units from 100 kVA; other sources give 0.9–1.2 m), plus room above it to open panels. With the largest open unit in this class, one generator needs a room of at least about 6.2 × 4.4 m.
  • When installing more than one unit, leave about 2 m between generators.

Ventilation

Outlet ≈ 1.5× radiator

  • Provide an air inlet behind the generator and an outlet in front of the radiator. As a general guide, the outlet is about 1.5× the radiator core area and the inlet 1.5–2× (louvres cut the free area by about 25%). Keep the room no more than about 7–10 °C above outdoor air; above 40 °C the generator needs derating.
  • Fit a duct adaptor from the radiator to the outlet so hot air does not circulate back into the room.

Foundation

≥ 2× unit weight

  • A concrete foundation of at least about 2× the generator's weight, extending 150–300 mm beyond the skid on every side, with vibration isolators between the skid and the foundation. Let the concrete cure for 28 days before loading. Dry weight of the open units in this class: 2–3.5 tonnes.

Day tank

350–450 L / 8 hours

  • Fuel use at 75% load: 44–56 L/hr, or about 350–450 L for 8 hours of running. Size the day tank from this; for longer running add a bulk tank with a transfer pump.
  • NFPA 37 limits a tank inside the generator room to 2,500 L unless it has its own fire-rated room; local regulations also apply.

Exhaust

Backpressure ≤ datasheet

  • A flexible connector at the engine outlet; pipework supported on its own so it does not load the engine, insulated and fitted with a rain cap. Choose the pipe and silencer so backpressure stays within the engine datasheet limit; avoid long runs and many bends. Discharge away from the air inlet.

Configuration

Open · Silent · Mobile

  • Open units for a generator room; silent canopy units for outdoors.
  • An ATS/AMF panel for grid backup; a synchronizing panel when two or more units run in parallel.
Projects

Generator Projects Around 300 kVA

Projects from our project list with units of around 300 kVA.

15 projects with units of around 300 kVA in our 2021–2026 project list. Client names are not shown.

  • Baudouin 300 kVA

    School

    Lampung Selatan, Lampung · 2026

  • Cummins 300 kVA

    Government office

    South Jakarta, Jakarta · 2025

  • Cummins 300 kVA

    Public facility

    Magelang, Central Java · 2024

  • Cummins 300 kVA

    University

    Depok, West Java · 2023

  • Cummins 300 kVA

    Power plant

    Sofifi, North Maluku · 2023

  • Cummins 300 kVA

    Retail & commercial

    Surabaya, East Java · 2021

  • Baudouin 300 kVA

    School

    Lampung Timur, Lampung · 2026

  • Baudouin 300 kVA

    School

    Minahasa, North Sulawesi · 2026

FAQ

Frequently Asked Questions

How much does a 300 kVA generator cost?

The price of a 300 kVA generator depends on the engine brand, the configuration (open type, silent canopy, silent mobile), an ATS/AMF or synchronizing panel, installation and commissioning, the delivery location, and the warranty and after-sales service. Use Request a Quote with your requirements and our sales team will send a quotation. What shapes a generator price

How many kW is a 300 kVA generator?

At the 0.8 power factor commonly used for generators, 300 kVA equals 240 kW. The exact kW of each model is on its specification page.

How much diesel does a 300 kVA generator use?

At 75% load, the 300 kVA prime generators in our catalogue use about 44–56 L/hr, depending on the engine brand and model. Fuel use at 50% and 100% load is on each model's page.

Should I choose 300 kVA prime or standby?

Choose a 300 kVA prime model if the generator is the main power source or runs long hours with a varying load. If you need 300 kVA only as backup during grid outages, a model with a 300 kVA standby rating (and a slightly lower prime rating) is usually enough and more economical.

Conductorjasa industrial generator distribution for power projects across Indonesia
By the Numbers

Trusted by Various Companies

Decades of experience and a portfolio of projects across many sectors reflect our commitment to quality.

Our clients

  • Otsuka
  • BCA
  • Santos Jaya Abadi
  • Bank Indonesia
  • Telkom Indonesia
  • Adhi Karya
  • IKEA
  • JW Marriott
  • Spazio
  • Universitas Brawijaya
  • PUPR
  • Siloam Hospitals
  • Djarum
  • Avian Brands
  • PLN
  • Waskita
  • KAI
  • Ciputra World
  • Hero
  • Golden Palace Hotel
  • Institut Teknologi Bandung
  • Universitas Negeri Surabaya
  • Pemerintah Kota Mataram
  • Kievit
  • Gudang Garam
  • Polygon
  • Pertamina Geothermal Energy
  • WIKA
  • INKA
  • Giant
  • Ibis Hotel
  • Universitas Gadjah Mada
  • Universitas Ciputra
  • Pemerintah Kota Surabaya
  • Huawei
  • MNC
  • Kapal Api
  • PGN
  • PP Properti
  • Bulog
  • Transmart
  • Vasa Hotel
  • Westown View
  • Universitas Airlangga
  • Kementerian Sosial
  • National Hospital
Conductorjasa generator assembly workshop in Surabaya
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.