Cummins Generator Options
With experience since 1977 as a Cummins generator distributor, we provide a wide range of generators for power needs across various sectors. Available in capacities from 20 kVA to 3350 kVA, featuring JERBINDO and VOLTRAGEN brands.
JERBINDO Power Systems
Integrated power generation systems, from industrial diesel generators and electrical panels to systems customized for the requirements of each project.
VOLTRAGEN
15–60 kVA silent generators for clinics, shops, restaurants, hotels, schools, offices, and homes, keeping operations running when the power goes out.
OEM for Global Engine Brands
Appointed as Original Equipment Manufacturer for Cummins G-Drive, DEUTZ, Mitsubishi Heavy Industries, and Baudouin PowerKit.
TKDN & e-Catalogue
JERBINDO and VOLTRAGEN products are TKDN certified and listed on the e-Catalogue for government projects.

Powered by
Other Engine Options
About Cummins Engines
Cummins was founded in 1919 in Columbus, Indiana, USA. Its power generation business grew from Onan, a generator maker since 1920 that became fully part of Cummins in 1992. We are an appointed OEM for Cummins G-Drive engines.
- 1919Cummins Engine Company was founded in Columbus, Indiana, USA.
- 1992Full acquisition of Onan, a generator maker since 1920, became the base of Cummins power generation.
- TodayG-Drive engines from the B and C series up to KTA50 and QSK95 power generators from tens to thousands of kVA.
Engine series in our range: 4B3.9, 4BTA3.9, 6BTA5.9, 6CTA8.3, 6LTAA9.5, NTA855, KTA19, KTA38, KTA50, QSK95
Best suited for
- Mining
- Factories & manufacturing
- Construction projects
- Plantations
- Data centers
- Commercial buildings

Key Strengths
The widest model choice
More than 100 Cummins-powered generator models in our catalogue, from 20 kVA to 3350 kVA.
Built for heavy loads
The NTA855, KTA19, KTA38 and KTA50 are known for prime duty in mining, factories and projects.
Container units
Containerised units are easy to set up on open sites and moving projects.
Wide service network
Parts and technicians for Cummins engines are within reach across much of Indonesia.
Your One-Stop Generator Solution
We provide more than generators, supporting installation, testing, and maintenance to help keep your generator running reliably.

Installation
Generator-set installation, ATS/AMF panel, commissioning, system synchronization, electrical integration, and testing.

Maintenance
Preventive maintenance, routine inspections, performance testing, oil and filter replacement, component checks, and ongoing maintenance.

Service & Spare Parts
Troubleshooting, repairs, spare parts replacement, overhauls, engine and alternator repairs, and performance restoration.
Cummins Generators for Various Sectors
As a Cummins generator distributor, we provide a range of generator options for different sectors, each with varying power requirements and operating conditions.

Data Centers
Standby power that keeps servers, networks, and digital infrastructure operating without interruption.
31 projects
View project list
Hospitality
Backup power that keeps guests comfortable and hotel services and building systems running.
123 projects
View project list
Hospitals, Clinics, Laboratories & Other Healthcare Facilities
Emergency power for medical equipment, laboratories, and healthcare services that cannot afford interruption.
117 projects
View project list
Educational Institutions
Keeping learning activities, laboratories, and school and campus facilities operating reliably.
71 projects
View project list
Manufacturing
Keeping production lines, machinery, and control systems running when the main supply is disrupted.
123 projects
View project list
Office & Commercial Buildings
Standby power for safety systems, elevators, lighting, information technology, and daily building operations.
247 projects
View project list
Power & Utilities
Power systems for generation sites, utility networks, and remote locations with demanding loads.
96 projects
View project list
Retail & Trade
Supporting lighting, refrigeration, security, and sales activity when grid power is interrupted.
61 projects
View project list
Financial Institutions
Backup power for banking systems, server rooms, and customer services that must always be available.
28 projects
View project list
Airports
Standby power for navigation systems, lighting, and terminal facilities that support flight safety.
53 projects
View project list
Food & Beverage
Keeping processing, cold storage, and packaging running so product quality is protected.
20 projects
View project list
Water Utilities
Power for pumps, water treatment plants, and clean-water distribution networks.
42 projects
View project list
Aquaculture
Power for aerators, pumps, and chillers that protect water quality and harvests.
14 projects
View project list
Residential
Backup power for apartments and housing estates that keeps elevators, water pumps, and lighting on.
38 projects
View project listCummins-Powered Generator Models
All JERBINDO generator models with Cummins engines, grouped by capacity, with prime and standby ratings. Select a model for full specifications, fuel use and dimensions.
Up to 50 kVA
9 model
| Model | Prime kVA | Standby kVA |
|---|---|---|
| CJPS C-20 WP4B3.9-G11 | 20 | 22 |
| CJPS C-25 WP4B3.9-G1 | 25 | 27.5 |
| CJPS C-28 WP4BT3.9-G1 | 28 | 30.8 |
| CJPS C-30 WP4BT3.9-G1 | 30 | 33 |
| CJPS C-30 WP24BT3.9-G12 | 30 | 33 |
| CJPS C-35 WP4BT3.9-G1 | 35 | 38.5 |
| CJPS C-40 WP4BT3.9-G2 | 40 | 44 |
| CJPS C-43 WP4BTA3.9-G2 | 43 | 47.3 |
| CJPS C-50 WP4BTA3.9-G2 | 50 | 55 |
51–150 kVA
11 model
| Model | Prime kVA | Standby kVA |
|---|---|---|
| CJPS C-60 WP14BTA3.9-G2 | 60 | 66 |
| CJPS C-60 WP24BTA3.9-G11 | 60 | 66 |
| CJPS C-80 WP4BTA3.9-G11 | 80 | 88 |
| CJPS O-80 WPQSB5-G3 | 80 | 88 |
| CJPS C-100 WP6BT5.9-G2 | 100 | 110 |
| CJPS O-100 WPQSB5-G5 | 100 | 110 |
| CJPS C-113 WP6BTA5.9G2 | 113 | 124.3 |
| CJPS C-125 WP6BTAA5.9G2 | 125 | 137.5 |
| CJPS O-135 WPQSB5-G6 | 135 | 148.5 |
| CJPS C-138 WP6BTAA5.9G2 | 138 | 151.8 |
| CJPS C-150 WP6BTAA5.9-G12 | 150 | 165 |
151–300 kVA
20 model
| Model | Prime kVA | Standby kVA |
|---|---|---|
| CJPS O-160 WPQSB7-G3 | 160 | 176 |
| CJPS C-175 WP6CTA8.3-G2 | 175 | 192.5 |
| CJPS C-180 WP6CTA8.3-G2 | 180 | 198 |
| CJPS O-181 WPQSB7-G4 | 181 | 199.1 |
| CJPS C-188 WP6CTA8.3-G2 | 188 | 206.8 |
| CJPS C-200 WP6CTAA8.3-G2 | 200 | 220 |
| CJPS O-200 WPQSB7G5 | 200 | 220 |
| CJPS C-225 WP6LTAA8.9G2 | 225 | 247.5 |
| CJPS O-225 WPQSL9-G2 | 225 | 247.5 |
| CJPS C-250 WP16LTAA8.9G2 | 250 | 275 |
| CJPS C-250 WP3 (CCEC)MTA11-G2A | 250 | 275 |
| CJPS C-250 WP3 (DCEC)QSL8.9-G4 | 250 | 275 |
| CJPS C-250 WP4NT855-GA | 250 | 275 |
| CJPS O-250 WPQSL9-G3 | 250 | 275 |
| CJPS C-275 WP16LTAA9.5-G3 | 275 | 302.5 |
| CJPS C-275 WP2NTA855.G1A | 275 | 302.5 |
| CJPS O-275 WPQSL9-G4 | 275 | 302.5 |
| CJPS C-300 WP (CCEC)NTA855-G1A | 300 | 330 |
| CJPS C-300 WP (DCEC)6LTAA9.5-G1 | 300 | 330 |
| CJPS O-300 WPQSL9-G7 | 300 | 330 |
301–600 kVA
29 model
| Model | Prime kVA | Standby kVA |
|---|---|---|
| CJPS C-313 WP1NTA855-G1B | 313 | 344.3 |
| CJPS C-313 WP2NTA855-G2 | 313 | 344.3 |
| CJPS C-313 WP3MTAA11-G3 | 313 | 344.3 |
| CJPS C-325 WP6LTAA9.5-G1 | 325 | 357.5 |
| CJPS C-350 WP1QSZ13-G6 | 350 | 385 |
| CJPS C-350 WP2NTA855-G2A | 350 | 385 |
| CJPS C-350 WP3NTA855-G4 | 350 | 385 |
| CJPS C-375 WP16ZTAA13-G3 | 375 | 412.5 |
| CJPS C-375 WP2NTAA855-G7 | 375 | 412.5 |
| CJPS C-400 WP1QSZ13-G7 | 400 | 440 |
| CJPS C-400 WP2NTAA855-G7A | 400 | 440 |
| CJPS C-400WPQSG12-G4 | 400 | 440 |
| CJPS C-438 WP6ZTAA13-G2 | 438 | 481.8 |
| CJPS O-396 WPNTA855-G7 | 440 | 484 |
| CJPS C-450 WP16ZTAA13-G4 | 450 | 495 |
| CJPS C-450 WP2QSZ13-G5 | 450 | 495 |
| CJPS C-450 WP3KTA19-G3 | 450 | 495 |
| CJPS O-450 WPQSX15-G6 | 450 | 495 |
| CJPS C-500 WPQSZ13-G10 | 500 | 550 |
| CJPS C-500 WP1 (CCEC)QSZ13-G3 | 500 | 550 |
| CJPS C-500 WP1 (DCEC)QSZ13-G3 | 500 | 550 |
| CJPS C-500 WP2KTA19-G3A | 500 | 550 |
| CJPS C-500 WP3KTA19-G4 | 500 | 550 |
| CJPS O-500 WPQSX15-G8 | 500 | 550 |
| CJPS C-525 WPKTAA19-G5 | 525 | 577.5 |
| CJPS C-575 WPKTAA19-G6 | 575 | 632.5 |
| CJPS C-580 WPKTA19G8 | 580 | 638 |
| CJPS C-600 WPKTA19G8A | 600 | 660 |
| CJPS C-600-WPKTAA19-G6 | 600 | 660 |
601–1000 kVA
17 model
| Model | Prime kVA | Standby kVA |
|---|---|---|
| CJPS C-620 WPKTAA19-G6A | 620 | 682 |
| CJPS C-625 WPKTAA19-G6A | 625 | 687.5 |
| CJPS O-625 WPVTA28-G5 | 625 | 687.5 |
| CJPS O-636 WPVTA28-G5 | 636 | 699.6 |
| CJPS C-650 WPQSK19-G4 | 650 | 715 |
| CJPS C-650 WP-KTAKTA19G9A | 650 | 715 |
| CJPS C-725 WPKT38-GA | 725 | 797.5 |
| CJPS C-750 WPKTA38-G2 | 750 | 825 |
| CJPS C-750 WP-QSKQSK19-G20 | 750 | 825 |
| CJPS O-750 WPVTA28-G6 | 750 | 825 |
| CJPS C-800 WPKTA38-G2B | 800 | 880 |
| CJPS O-800 WPQSK23-G3 | 800 | 880 |
| CJPS C-900 WPKTA38-G2A | 900 | 990 |
| CJPS O-900 WPQST30-G3 | 900 | 990 |
| CJPS C-1000 WPKTA38-G5 | 1000 | 1100 |
| CJPS O-1000 WP1QST30-G4 | 1000 | 1100 |
| CJPS O-1000 WP2KTA38-G5 | 1000 | 1100 |
1001–2000 kVA
10 model
| Model | Prime kVA | Standby kVA |
|---|---|---|
| CJPS C-1125 WPKTA38-G9 | 1125 | 1237.5 |
| CJPS C-1250 WP1QSK38-G5 | 1250 | 1375 |
| CJPS C-1250 WP2KTA50-G3 | 1250 | 1375 |
| CJPS C-1375 WPKTA50-G8 | 1375 | 1512.5 |
| CJPS O-1400 WPKTA50-G8 | 1400 | 1540 |
| CJPS C-1500 WPKTA50-GS8 | 1500 | 1650 |
| CJPS O-1650 WPQSK50-G7 | 1650 | 1815 |
| CJPS C-1705 WPQSK50-G13 | 1705 | 1875.5 |
| CJPS O-1875 WPQSK60-G3 | 1875 | 2062.5 |
| CJPS O-2000 WPQSK60-G4 | 2000 | 2200 |
Above 2000 kVA
6 model
| Model | Prime kVA | Standby kVA |
|---|---|---|
| CJPS O-2250 WPQSK60-G8 | 2250 | 2475 |
| CJPS O-2500 WPQSK60-G23 | 2500 | 2750 |
| CJPS O-2500 WP-2.4kVQSK60-G23 | 2500 | 2750 |
| CJPS O-2750 WPQSK78-G9 | 2750 | 3025 |
| CJPS O-2750 WP-2400 VQSK78-G9 | 2750 | 3025 |
| CJPS O-3350 WP1QSK95-G4 | 3350 | 3685 |
All JERBINDO units ship as open type, with a silent canopy on request and a silent container from 750 kVA.
Cummins Generator Projects
Cummins-powered generator projects from our project list.
Frequently Asked Questions
What capacities are available for Cummins generators?
JERBINDO and VOLTRAGEN generators with Cummins engines range from 20 kVA to 3350 kVA (prime), open type with silent or container options.
What is the difference between prime and standby power?
Prime power is for continuous running with a varying load; standby is the maximum output for backup when the grid fails. The model table shows both.
Are container-type Cummins generators available?
Yes. Several Cummins-powered models come in a container, suited to mining, projects and open sites.
Are Cummins-powered generators TKDN certified?
Yes. JERBINDO and VOLTRAGEN generators are TKDN certified and listed on the e-Catalogue for government projects.

Trusted by Various Companies
Decades of experience and a portfolio of projects across many sectors reflect our commitment to quality.
Our clients
Explore More Generator Solutions

Find the Right Industrial Generator Solution
Discuss your power requirements with our sales and service team to get the right products and services.