Skip to main content
Generator JERBINDO CJPS C-1500 WP
Diesel Generator Set | Cummins

JERBINDO CJPS C-1500 WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO CJPS C-1500 WP — Open Frame
Generator JERBINDO CJPS C-1500 WP — Silent

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
1500 kVA
1200 kW
Standby Power
1650 kVA
1320 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
238 L/hr

JERBINDO CJPS C-1500 WP is a diesel generator rated at 1500 kVA prime and 1650 kVA standby, powered by a water-cooled Cummins KTA50-GS8 engine with a Stamford alternator. The unit is designed for power needs in data center, hospital, commercial complex, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Data Center
  • Hospital
  • Commercial Complex

Engine System

Cooling SystemWater Cooled
Engine BrandCummins
Engine ModelKTA50-GS8

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement16 V
Cylinders16
Displacement50.3 L
Bore159 mm
Stroke159 mm
GovernorElectronic
Max Engine Power1429 kWm
Oil Capacity178 L

Alternator

Brand & ModelStamford S7L1D-C41
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output1500 kVA | 1200 kW
Standby Output1650 kVA | 1320 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)5700 x 2270 x 2550 mm12192 x 2438 x 2896 mm
Dry Weight14000 kg16000 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load309 L/hr
  • 75% Typical Load238 L/hr
  • 50% Light Load167 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 238 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO CJPS C-1500 WP best?

This unit is designed for data center, hospital, commercial complex. With water-cooled operation and a prime rating of 1500 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 1500 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 1650 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. A silent container option is also available from 1000 kVA. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO BJPS-1500-WP Open Type — Open Frame
Generator JERBINDO BJPS-1500-WP Open Type — Silent
JERBINDO

BJPS-1500-WP

Engine: Baudouin 12M33G1650/5

Prime
1500 kVA
Standby
1650 kVA
Alternator
Leroy Somer LSA 50.2 L8
Cooling
Water Cooled

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO PJPS-1500 WP1 Open Type — Open Frame
Generator JERBINDO PJPS-1500 WP1 Open Type — Silent
JERBINDO

PJPS-1500 WP1

Engine: Perkins 4012-46TAG2A

Prime
1500 kVA
Standby
1650 kVA
Alternator
Stamford S7L1D-C41
Cooling
Water Cooled
Fuel @ 75%
237 L/hr

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO MJPS-1500-C-leroy Open Type — Open Frame
Generator JERBINDO MJPS-1500-C-leroy Open Type — Silent
JERBINDO

MJPS-1500-C-leroy

Engine: Mitsubishi S12R-PTAA2-C

Prime
1500 kVA
Standby
1650 kVA
Alternator
Leroy-Somer LSA50.2 L8
Cooling
Water Cooled
Fuel @ 75%
237 L/hr

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO MJPS-1500-Size Open Type — Open Frame
Generator JERBINDO MJPS-1500-Size Open Type — Silent
JERBINDO

MJPS-1500-Size

Engine: Mitsubishi S12R-PTAA2

Prime
1500 kVA
Standby
1650 kVA
Alternator
Stamford PI 734 C
Cooling
Water Cooled
Fuel @ 75%
250 L/hr

Open TypeOption: SilentOption: Container

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.