CJPS C-375 WP2
Engine: Cummins NTAA855-G7
- Prime
- 375 kVA
- Standby
- 412.5 kVA
- Alternator
- Stamford S4L1D-F41
- Cooling
- Water Cooled
- Fuel @ 75%
- 71 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO CJPS C-375 WP1 is a diesel generator rated at 375 kVA prime and 412.5 kVA standby, powered by a water-cooled Cummins 6ZTAA13-G3 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Cummins |
| Engine Model | 6ZTAA13-G3 |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 6 in-line |
| Cylinders | 6 |
| Displacement | 14 L |
| Bore | 130 mm |
| Stroke | 163 mm |
| Governor | Electronic |
| Max Engine Power | 380 kWm |
| Oil Capacity | 45 L |
| Brand & Model | Stamford S4L1D-F41 |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 375 kVA | 300 kW |
|---|---|
| Standby Output | 412.5 kVA | 330 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 3485 x 1155 x 1640 mm | 4810 x 1500 x 2260 mm |
| Dry Weight | 3600 kg | 4870 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 375 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 375 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 412.5 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Cummins NTAA855-G7
Open TypeOption: Silent



Engine: Baudouin 6M21G400/5
Open TypeOption: Silent



Engine: Deutz BF6M 1015 CP
Open TypeOption: Silent



Engine: Cummins QSZ13-G6
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.