Skip to main content
Generator JERBINDO CJPS C-350 WP1
Diesel Generator Set | Cummins

JERBINDO CJPS C-350 WP1

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO CJPS C-350 WP1 — Open Frame
Generator JERBINDO CJPS C-350 WP1 — Silent
Generator JERBINDO CJPS C-350 WP1 — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
350 kVA
280 kW
Standby Power
385 kVA
308 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
65 L/hr

JERBINDO CJPS C-350 WP1 is a diesel generator rated at 350 kVA prime and 385 kVA standby, powered by a water-cooled Cummins QSZ13-G6 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Hospital
  • Hotel
  • Office Tower

Engine System

Cooling SystemWater Cooled
Engine BrandCummins
Engine ModelQSZ13-G6

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement6 in-line
Cylinders6
Displacement13 L
Bore130 mm
Stroke163 mm
GovernorElectronic
Max Engine Power328 kWm
Oil Capacity39 L

Alternator

Brand & ModelStamford S4L1D-E41
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output350 kVA | 280 kW
Standby Output385 kVA | 308 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)2890 x 1100 x 1650 mm4480 x 1130 x 2270 mm
Dry Weight3380 kg4060 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load82 L/hr
  • 75% Typical Load65 L/hr
  • 50% Light Load48 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 65 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO CJPS C-350 WP1 best?

This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 350 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 350 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 385 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-350 WP2 Open Type — Open Frame
Generator JERBINDO CJPS C-350 WP2 Open Type — Silent
Generator JERBINDO CJPS C-350 WP2 Open Type — Silent Mobile
JERBINDO

CJPS C-350 WP2

Engine: Cummins NTA855-G2A

Prime
350 kVA
Standby
385 kVA
Alternator
Stamford S4L1D-E41
Cooling
Water Cooled
Fuel @ 75%
54.9 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-350 WP3 Open Type — Open Frame
Generator JERBINDO CJPS C-350 WP3 Open Type — Silent
Generator JERBINDO CJPS C-350 WP3 Open Type — Silent Mobile
JERBINDO

CJPS C-350 WP3

Engine: Cummins NTA855-G4

Prime
350 kVA
Standby
385 kVA
Alternator
Stamford S4L1D-E41
Cooling
Water Cooled
Fuel @ 75%
57 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO DJPS-350 WP Open Type — Open Frame
Generator JERBINDO DJPS-350 WP Open Type — Silent
Generator JERBINDO DJPS-350 WP Open Type — Silent Mobile
JERBINDO

DJPS-350 WP

Engine: Deutz BF6M 1015 C

Prime
350 kVA
Standby
385 kVA
Alternator
Stamford HCI 434 E
Cooling
Water Cooled
Fuel @ 75%
57.4 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO PJPS-350 WP Open Type — Open Frame
Generator JERBINDO PJPS-350 WP Open Type — Silent
Generator JERBINDO PJPS-350 WP Open Type — Silent Mobile
JERBINDO

PJPS-350 WP

Engine: Perkins 2206 C-E13TAG2

Prime
350 kVA
Standby
385 kVA
Alternator
Stamford S4L1D-E4
Cooling
Water Cooled
Fuel @ 75%
54 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.