CJPS C-350 WP1
Engine: Cummins QSZ13-G6
- Prime
- 350 kVA
- Standby
- 385 kVA
- Alternator
- Stamford S4L1D-E41
- Cooling
- Water Cooled
- Fuel @ 75%
- 65 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO CJPS C-350 WP2 is a diesel generator rated at 350 kVA prime and 385 kVA standby, powered by a water-cooled Cummins NTA855-G2A engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Cummins |
| Engine Model | NTA855-G2A |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 6 in-line |
| Cylinders | 6 |
| Displacement | 14 L |
| Bore | 140 mm |
| Stroke | 152 mm |
| Governor | Electronic |
| Max Engine Power | 343 kWm |
| Oil Capacity | 38.6 L |
| Brand & Model | Stamford S4L1D-E41 |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 350 kVA | 280 kW |
|---|---|
| Standby Output | 385 kVA | 308 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 3090 x 1300 x 1750 mm | 4200 x 1630 x 2600 mm |
| Dry Weight | 3380 kg | 3800 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 350 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 350 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 385 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Cummins QSZ13-G6
Open TypeOption: Silent



Engine: Cummins NTA855-G4
Open TypeOption: Silent



Engine: Deutz BF6M 1015 C
Open TypeOption: Silent



Engine: Perkins 2206 C-E13TAG2
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.