CJPS C-180 WP
Engine: Cummins 6CTA8.3-G2
- Prime
- 180 kVA
- Standby
- 198 kVA
- Alternator
- Stamford UCI274G
- Cooling
- Water Cooled
- Fuel @ 75%
- 31 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO CJPS O-181 WP is a diesel generator rated at 181 kVA prime and 199.1 kVA standby, powered by a water-cooled Cummins QSB7-G4 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Cummins |
| Engine Model | QSB7-G4 |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 6 in-line |
| Cylinders | 6 |
| Displacement | 6.69 L |
| Bore | 107 mm |
| Stroke | 124 mm |
| Governor | Electronic |
| Max Engine Power | 196 kWm |
| Oil Capacity | 18.9 L |
| Brand & Model | Stamford UCI274G |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 181 kVA | 145 kW |
|---|---|
| Standby Output | 199.1 kVA | 159.5 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 2500 x 1000 x 1500 mm | 3600 x 1400 x 2400 mm |
| Dry Weight | 1600 kg | 1840 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 181 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 181 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 199.1 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Cummins 6CTA8.3-G2
Open TypeOption: Silent



Engine: Deutz BF 6M 1013 FC
Open TypeOption: Silent



Engine: Perkins 1106A-70TAG3
Open TypeOption: Silent



Engine: Cummins 6CTA8.3-G2
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.