Skip to main content
Generator JERBINDO CJPS C-180 WP
Diesel Generator Set | Cummins

JERBINDO CJPS C-180 WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO CJPS C-180 WP — Open Frame
Generator JERBINDO CJPS C-180 WP — Silent
Generator JERBINDO CJPS C-180 WP — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
180 kVA
144 kW
Standby Power
198 kVA
158.4 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
31 L/hr

JERBINDO CJPS C-180 WP is a diesel generator rated at 180 kVA prime and 198 kVA standby, powered by a water-cooled Cummins 6CTA8.3-G2 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Hospital
  • Hotel
  • Office Tower

Engine System

Cooling SystemWater Cooled
Engine BrandCummins
Engine Model6CTA8.3-G2

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement6 in-line
Cylinders6
Displacement8.3 L
Bore114 mm
Stroke135 mm
GovernorElectrical
Max Engine Power180 kWm
Oil Capacity27.6 L

Alternator

Brand & ModelStamford UCI274G
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output180 kVA | 144 kW
Standby Output198 kVA | 158.4 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)2500 x1000 x 1510 mm3600 x 1400 x 2400 mm
Dry Weight1600 kg1725 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load42 L/hr
  • 75% Typical Load31 L/hr
  • 50% Light Load21 L/hr

Tank capacity: 300 L

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 31 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO CJPS C-180 WP best?

This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 180 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 180 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 198 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO DJPS-180 WP Open Type — Open Frame
Generator JERBINDO DJPS-180 WP Open Type — Silent
Generator JERBINDO DJPS-180 WP Open Type — Silent Mobile
JERBINDO

DJPS-180 WP

Engine: Deutz BF 6M 1013 FC

Prime
180 kVA
Standby
198 kVA
Alternator
Stamford UCI 274 G
Cooling
Water Cooled
Fuel @ 75%
30.0 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO PJPS-180 WP Open Type — Open Frame
Generator JERBINDO PJPS-180 WP Open Type — Silent
Generator JERBINDO PJPS-180 WP Open Type — Silent Mobile
JERBINDO

PJPS-180 WP

Engine: Perkins 1106A-70TAG3

Prime
180 kVA
Standby
198 kVA
Alternator
Stamford UCI 274 G
Cooling
Water Cooled
Fuel @ 75%
31 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS O-181 WP Open Type — Open Frame
Generator JERBINDO CJPS O-181 WP Open Type — Silent
Generator JERBINDO CJPS O-181 WP Open Type — Silent Mobile
JERBINDO

CJPS O-181 WP

Engine: Cummins QSB7-G4

Prime
181 kVA
Standby
199.1 kVA
Alternator
Stamford UCI274G
Cooling
Water Cooled
Fuel @ 75%
34 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-175 WP Open Type — Open Frame
Generator JERBINDO CJPS C-175 WP Open Type — Silent
Generator JERBINDO CJPS C-175 WP Open Type — Silent Mobile
JERBINDO

CJPS C-175 WP

Engine: Cummins 6CTA8.3-G2

Prime
175 kVA
Standby
192.5 kVA
Alternator
Stamford UCI274H
Cooling
Water Cooled
Fuel @ 75%
31 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.