Skip to main content
Generator JERBINDO CJPS O-636 WP
Diesel Generator Set | Cummins

JERBINDO CJPS O-636 WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO CJPS O-636 WP — Open Frame
Generator JERBINDO CJPS O-636 WP — Silent
Generator JERBINDO CJPS O-636 WP — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
636 kVA
509 kW
Standby Power
699.6 kVA
559.9 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
104 L/hr

JERBINDO CJPS O-636 WP is a diesel generator rated at 636 kVA prime and 699.6 kVA standby, powered by a water-cooled Cummins VTA28-G5 engine with a Stamford alternator. The unit is designed for power needs in data center, hospital, commercial complex, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Data Center
  • Hospital
  • Commercial Complex

Engine System

Cooling SystemWater Cooled
Engine BrandCummins
Engine ModelVTA28-G5

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement12 in-line
Cylinders12
Displacement28 L
Bore139.7 mm
Stroke152.4 mm
GovernorElectronic
Max Engine Power612 kWm
Oil Capacity38 L

Alternator

Brand & ModelStamford S5L1D-F4
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output636 kVA | 509 kW
Standby Output699.6 kVA | 559.9 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)3600 x 1700 x 2300 mm4900 x 1800 x 2700 mm
Dry Weight4950 kg5700 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load140 L/hr
  • 75% Typical Load104 L/hr
  • 50% Light Load73 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 104 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO CJPS O-636 WP best?

This unit is designed for data center, hospital, commercial complex. With water-cooled operation and a prime rating of 636 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 636 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 699.6 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-625 WP Open Type — Open Frame
Generator JERBINDO CJPS C-625 WP Open Type — Silent
Generator JERBINDO CJPS C-625 WP Open Type — Silent Mobile
JERBINDO

CJPS C-625 WP

Engine: Cummins KTAA19-G6A

Prime
625 kVA
Standby
687.5 kVA
Alternator
Stamford S5L1D-F4
Cooling
Water Cooled
Fuel @ 75%
95.2 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS O-625 WP Open Type — Open Frame
Generator JERBINDO CJPS O-625 WP Open Type — Silent
Generator JERBINDO CJPS O-625 WP Open Type — Silent Mobile
JERBINDO

CJPS O-625 WP

Engine: Cummins VTA28-G5

Prime
625 kVA
Standby
687.5 kVA
Alternator
Stamford S5L1D-F4
Cooling
Water Cooled
Fuel @ 75%
104 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-650 WP Open Type — Open Frame
Generator JERBINDO CJPS C-650 WP Open Type — Silent
Generator JERBINDO CJPS C-650 WP Open Type — Silent Mobile
JERBINDO

CJPS C-650 WP

Engine: Cummins QSK19-G4

Prime
650 kVA
Standby
715 kVA
Alternator
Stamford S5L1D-F4
Cooling
Water Cooled
Fuel @ 75%
111 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-650 WP-KTA Open Type — Open Frame
Generator JERBINDO CJPS C-650 WP-KTA Open Type — Silent
Generator JERBINDO CJPS C-650 WP-KTA Open Type — Silent Mobile
JERBINDO

CJPS C-650 WP-KTA

Engine: Cummins KTA19G9A

Prime
650 kVA
Standby
715 kVA
Alternator
Stamford S5L1D-F4
Cooling
Water Cooled
Fuel @ 75%
101 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.