Skip to main content
Generator JERBINDO CJPS C-600-WP
Diesel Generator Set | Cummins

JERBINDO CJPS C-600-WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO CJPS C-600-WP — Open Frame
Generator JERBINDO CJPS C-600-WP — Silent
Generator JERBINDO CJPS C-600-WP — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
600 kVA
480 kW
Standby Power
660 kVA
528 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
95.2 L/hr

JERBINDO CJPS C-600-WP is a diesel generator rated at 600 kVA prime and 660 kVA standby, powered by a water-cooled Cummins KTAA19-G6 engine with a Stamford alternator. The unit is designed for power needs in factory, commercial complex, project site, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Factory
  • Commercial Complex
  • Project Site

Engine System

Cooling SystemWater Cooled
Engine BrandCummins
Engine ModelKTAA19-G6

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement6 in-line
Cylinders6
Displacement19 L
Bore159 mm
Stroke159 mm
GovernorElectronic
Max Engine Power570 kWm
Oil Capacity37.9 L

Alternator

Brand & ModelStamford S5L1D-E4
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output600 kVA | 480 kW
Standby Output660 kVA | 528 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)3600 x 1680 x 2200 mm4900 x 1800 x 2600 mm
Dry Weight4950 kg5700 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load127.8 L/hr
  • 75% Typical Load95.2 L/hr
  • 50% Light Load63.9 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 95.2 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO CJPS C-600-WP best?

This unit is designed for factory, commercial complex, project site. With water-cooled operation and a prime rating of 600 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 600 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 660 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-600 WP Open Type — Open Frame
Generator JERBINDO CJPS C-600 WP Open Type — Silent
Generator JERBINDO CJPS C-600 WP Open Type — Silent Mobile
JERBINDO

CJPS C-600 WP

Engine: Cummins KTA19G8A

Prime
600 kVA
Standby
660 kVA
Alternator
Stamford S5L1D-E4
Cooling
Water Cooled
Fuel @ 75%
101 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO PJPS-600 WP Open Type — Open Frame
Generator JERBINDO PJPS-600 WP Open Type — Silent
Generator JERBINDO PJPS-600 WP Open Type — Silent Mobile
JERBINDO

PJPS-600 WP

Engine: Perkins 2806 C-E18TAG1A

Prime
600 kVA
Standby
660 kVA
Alternator
Stamford S5L1D-E4
Cooling
Water Cooled
Fuel @ 75%
90 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-580 WP Open Type — Open Frame
Generator JERBINDO CJPS C-580 WP Open Type — Silent
Generator JERBINDO CJPS C-580 WP Open Type — Silent Mobile
JERBINDO

CJPS C-580 WP

Engine: Cummins KTA19G8

Prime
580 kVA
Standby
638 kVA
Alternator
Stamford S5L1D-E4
Cooling
Water Cooled
Fuel @ 75%
101 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-620 WP Open Type — Open Frame
Generator JERBINDO CJPS C-620 WP Open Type — Silent
Generator JERBINDO CJPS C-620 WP Open Type — Silent Mobile
JERBINDO

CJPS C-620 WP

Engine: Cummins KTAA19-G6A

Prime
620 kVA
Standby
682 kVA
Alternator
Stamford S5L1D-F4
Cooling
Water Cooled
Fuel @ 75%
95.2 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.