CJPS C-600 WP
Engine: Cummins KTA19G8A
- Prime
- 600 kVA
- Standby
- 660 kVA
- Alternator
- Stamford S5L1D-E4
- Cooling
- Water Cooled
- Fuel @ 75%
- 101 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO PJPS-600 WP is a diesel generator rated at 600 kVA prime and 660 kVA standby, powered by a water-cooled Perkins 2806 C-E18TAG1A engine with a Stamford alternator. The unit is designed for power needs in data center, hospital, commercial complex, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Perkins |
| Engine Model | 2806 C-E18TAG1A |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 6 in-line |
| Cylinders | 6 |
| Displacement | 18.1 L |
| Bore | 145 mm |
| Stroke | 183 mm |
| Governor | Electronic |
| Max Engine Power | 593 kWm |
| Oil Capacity | 62 L |
| Brand & Model | Stamford S5L1D-E4 |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 600 kVA | 480 kW |
|---|---|
| Standby Output | 660 kVA | 528 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 3500 x 1550 x 2100 mm | 4900 x 1800 x 2600 mm |
| Dry Weight | 4298 kg | 4940 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
Tank capacity: 700 L
This unit is designed for data center, hospital, commercial complex. With water-cooled operation and a prime rating of 600 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 600 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 660 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Cummins KTA19G8A
Open TypeOption: Silent



Engine: Cummins KTAA19-G6
Open TypeOption: Silent



Engine: Cummins KTA19G8
Open TypeOption: Silent



Engine: Cummins KTAA19-G6A
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.