400 kVA Generator

Equal to 320 kW. Cummins, Baudouin, Deutz & Perkins engines, open and silent, with fuel use and dimensions compared.

View Catalogue
Overview

Getting to Know 400 kVA Generators

A 400 kVA generator is about 320 kW at a power factor of 0.8. This class serves hotels, hospitals, multi-storey buildings and mid-size factories.

The 400 kVA class offers several engine options, with fuel use and dimensions compared directly in the table.

Suited to

  • Hotels
  • Hospitals
  • Multi-storey buildings
  • Mid-size factories
  • Malls
  • Campuses

Prime or Standby?

Main power

400 kVA prime

5models
  • The generator is the main power source, for example at a site without grid power
  • It runs long hours every day with a varying load

e.g. CJPS C-400 WP1

Grid backup

400 kVA standby

1models
  • The generator only runs during grid outages
  • Prime slightly below 400 kVA, standby around 400 kVA: usually more economical

e.g. BJPS-375-WP

Model

400 kVA Generator Options

Every JERBINDO 400 kVA model by engine brand. Select a model for full specifications.

Cummins engine

Fuel at 75% (prime): 60–73.3 L/hr3 models
ModelPrime kVAStandby kVA
CJPS C-400 WP1QSZ13-G7400 kVA prime400440
CJPS C-400 WP2NTAA855-G7A400 kVA prime400440
CJPS C-400WPQSG12-G4400 kVA prime400440
Cummins Generator

Baudouin engine

1 models
ModelPrime kVAStandby kVA
BJPS-375-WP6M21G400/5400 kVA standby375400
Baudouin Generator

Deutz engine

Fuel at 75% (prime): 69.3 L/hr1 models
ModelPrime kVAStandby kVA
DJPS-400 WPBF8M 1015 C400 kVA prime400440
Deutz Generator

Perkins engine

Fuel at 75% (prime): 65 L/hr1 models
ModelPrime kVAStandby kVA
PJPS-400 WP2206 C-E13TAG3400 kVA prime400440
Perkins Generator
Installation

Generator Room Requirements

General guidance for the 400 kVA class from engine and generator makers' installation manuals. Final figures follow the installation drawings and datasheet of the chosen unit.

Minimum room, 1 unit
6.5 × 4.5 m
Open type (L × W × H)
2900–3500 × 1300–1500 × 1800–2100 mm
Silent canopy (L × W × H)
4200–4400 × 1600–1800 × 2600–2615 mm

Service clearance

1.5 m per side

  • Leave at least about 1.5 m of clear space on every side of the generator for maintenance (Cummins' guide for units from 100 kVA; other sources give 0.9–1.2 m), plus room above it to open panels. With the largest open unit in this class, one generator needs a room of at least about 6.5 × 4.5 m.
  • When installing more than one unit, leave about 2 m between generators.

Ventilation

Outlet ≈ 1.5× radiator

  • Provide an air inlet behind the generator and an outlet in front of the radiator. As a general guide, the outlet is about 1.5× the radiator core area and the inlet 1.5–2× (louvres cut the free area by about 25%). Keep the room no more than about 7–10 °C above outdoor air; above 40 °C the generator needs derating.
  • Fit a duct adaptor from the radiator to the outlet so hot air does not circulate back into the room.

Foundation

≥ 2× unit weight

  • A concrete foundation of at least about 2× the generator's weight, extending 150–300 mm beyond the skid on every side, with vibration isolators between the skid and the foundation. Let the concrete cure for 28 days before loading. Dry weight of the open units in this class: 3–4.9 tonnes.

Day tank

480–590 L / 8 hours

  • Fuel use at 75% load: 60–73.3 L/hr, or about 480–590 L for 8 hours of running. Size the day tank from this; for longer running add a bulk tank with a transfer pump.
  • NFPA 37 limits a tank inside the generator room to 2,500 L unless it has its own fire-rated room; local regulations also apply.

Exhaust

Backpressure ≤ datasheet

  • A flexible connector at the engine outlet; pipework supported on its own so it does not load the engine, insulated and fitted with a rain cap. Choose the pipe and silencer so backpressure stays within the engine datasheet limit; avoid long runs and many bends. Discharge away from the air inlet.

Configuration

Open · Silent · Mobile

  • Open units for a generator room; silent canopy units for outdoors.
  • An ATS/AMF panel for grid backup; a synchronizing panel for parallel operation of several units.
Projects

Generator Projects Around 400 kVA

Projects from our project list with units of around 400 kVA.

More project references, 2021–2026

9 projects with units of around 400 kVA in our 2021–2026 project list. Client names are not shown.

  • Baudouin 400 kVA

    Residential tower

    Nusantara Capital City (IKN) · 2025

  • Baudouin 400 kVA

    Substation & power grid

    West Java · 2025

  • Baudouin 400 kVA

    Hospital

    Manggarai Timur, East Nusa Tenggara · 2025

  • Cummins 400 kVA

    Government office

    Bandung, West Java · 2023

  • Perkins 400 kVA

    University

    Malang, East Java · 2022

  • Cummins 400 kVA

    Warehouse & cold storage

    Surabaya, East Java · 2021

  • Cummins 400 kVA

    Residential tower

    Nusantara Capital City (IKN) · 2024

  • Baudouin 400 kVA

    Substation & power grid

    Probolinggo, East Java · 2024

FAQ

Frequently Asked Questions

How much does a 400 kVA generator cost?

The price of a 400 kVA generator depends on the engine brand, the configuration (open type, silent canopy, silent mobile), an ATS/AMF or synchronizing panel, installation and commissioning, the delivery location, and the warranty and after-sales service. Use Request a Quote with your requirements and our sales team will send a quotation. What shapes a generator price

How many kW is a 400 kVA generator?

At the 0.8 power factor commonly used for generators, 400 kVA equals 320 kW. The exact kW of each model is on its specification page.

How much diesel does a 400 kVA generator use?

At 75% load, the 400 kVA prime generators in our catalogue use about 60–73.3 L/hr, depending on the engine brand and model. Fuel use at 50% and 100% load is on each model's page.

Should I choose 400 kVA prime or standby?

Choose a 400 kVA prime model if the generator is the main power source or runs long hours with a varying load. If you need 400 kVA only as backup during grid outages, a model with a 400 kVA standby rating (and a slightly lower prime rating) is usually enough and more economical.

Conductorjasa industrial generator distribution for power projects across Indonesia
By the Numbers

Trusted by Various Companies

Decades of experience and a portfolio of projects across many sectors reflect our commitment to quality.

Our clients

  • Otsuka
  • BCA
  • Santos Jaya Abadi
  • Bank Indonesia
  • Telkom Indonesia
  • Adhi Karya
  • IKEA
  • JW Marriott
  • Spazio
  • Universitas Brawijaya
  • PUPR
  • Siloam Hospitals
  • Djarum
  • Avian Brands
  • PLN
  • Waskita
  • KAI
  • Ciputra World
  • Hero
  • Golden Palace Hotel
  • Institut Teknologi Bandung
  • Universitas Negeri Surabaya
  • Pemerintah Kota Mataram
  • Kievit
  • Gudang Garam
  • Polygon
  • Pertamina Geothermal Energy
  • WIKA
  • INKA
  • Giant
  • Ibis Hotel
  • Universitas Gadjah Mada
  • Universitas Ciputra
  • Pemerintah Kota Surabaya
  • Huawei
  • MNC
  • Kapal Api
  • PGN
  • PP Properti
  • Bulog
  • Transmart
  • Vasa Hotel
  • Westown View
  • Universitas Airlangga
  • Kementerian Sosial
  • National Hospital
Conductorjasa generator assembly workshop in Surabaya
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.