1500 kVA Generator

Equal to 1200 kW. Mitsubishi, Cummins, Baudouin & Perkins engines, open and silent, with fuel use and dimensions compared.

View Catalogue
Overview

Getting to Know 1500 kVA Generators

A 1500 kVA (1.5 MVA) generator is about 1200 kW at a power factor of 0.8. This large class serves data centres, heavy industry, mining and large hospitals.

A silent container option is available for outdoor installation. Where one unit is not enough, several generators can be synchronized in parallel.

Suited to

  • Data centres
  • Heavy industry
  • Mining
  • Large hospitals
  • High-rise buildings

Prime or Standby?

Main power

1500 kVA prime

6models
  • The generator is the main power source, for example at a site without grid power
  • It runs long hours every day with a varying load

e.g. BJPS-1500-WP

Grid backup

1500 kVA standby

1models
  • The generator only runs during grid outages
  • Prime slightly below 1500 kVA, standby around 1500 kVA: usually more economical

e.g. CJPS C-1375 WP

Model

1500 kVA Generator Options

Every JERBINDO 1500 kVA model by engine brand. Select a model for full specifications.

Mitsubishi engine

Fuel at 75% (prime): 237–250 L/hr3 models
ModelPrime kVAStandby kVA
MJPS-1500-CS12R-PTAA2-C1500 kVA prime15001650
MJPS-1500-C-leroyS12R-PTAA2-C1500 kVA prime15001650
MJPS-1500-SizeS12R-PTAA21500 kVA prime15001650
Mitsubishi Generator

Cummins engine

Fuel at 75% (prime): 238 L/hr2 models
ModelPrime kVAStandby kVA
CJPS C-1500 WPKTA50-GS81500 kVA prime15001650
CJPS C-1375 WPKTA50-G81500 kVA standby13751512.5
Cummins Generator

Baudouin engine

1 models
ModelPrime kVAStandby kVA
BJPS-1500-WP12M33G1650/51500 kVA prime15001650
Baudouin Generator

Perkins engine

Fuel at 75% (prime): 237 L/hr1 models
ModelPrime kVAStandby kVA
PJPS-1500 WP14012-46TAG2A1500 kVA prime15001650
Perkins Generator
Installation

Generator Room Requirements

General guidance for the 1500 kVA class from engine and generator makers' installation manuals. Final figures follow the installation drawings and datasheet of the chosen unit.

Minimum room, 1 unit
8.7 × 5.3 m
Open type (L × W × H)
4800–5700 × 2150–2270 × 2430–2700 mm
Silent canopy (L × W × H)
7700–12192 × 2438–2800 × 2896–3150 mm

Service clearance

1.5 m per side

  • Leave at least about 1.5 m of clear space on every side of the generator for maintenance (Cummins' guide for units from 100 kVA; other sources give 0.9–1.2 m), plus room above it to open panels. With the largest open unit in this class, one generator needs a room of at least about 8.7 × 5.3 m.
  • When installing more than one unit, leave about 2 m between generators.
  • Also keep a route and door wide enough to bring the unit in and to remove large parts such as the radiator or alternator.

Ventilation

Outlet ≈ 1.5× radiator

  • Provide an air inlet behind the generator and an outlet in front of the radiator. As a general guide, the outlet is about 1.5× the radiator core area and the inlet 1.5–2× (louvres cut the free area by about 25%). Keep the room no more than about 7–10 °C above outdoor air; above 40 °C the generator needs derating.
  • Radiator airflow in this class is very large, so a radiator duct to the outside or a silent container outside the building is usually needed.

Foundation

≥ 2× unit weight

  • A concrete foundation of at least about 2× the generator's weight, extending 150–300 mm beyond the skid on every side, with vibration isolators between the skid and the foundation. Let the concrete cure for 28 days before loading. Dry weight of the open units in this class: 8.6–14 tonnes.
  • At this weight, the foundation and floor structure should be designed by a structural engineer.

Day tank

1900–2000 L / 8 hours

  • Fuel use at 75% load: 237–250 L/hr, or about 1900–2000 L for 8 hours of running. Size the day tank from this; for longer running add a bulk tank with a transfer pump.
  • NFPA 37 limits a tank inside the generator room to 2,500 L unless it has its own fire-rated room; local regulations also apply.

Exhaust

Backpressure ≤ datasheet

  • A flexible connector at the engine outlet; pipework supported on its own so it does not load the engine, insulated and fitted with a rain cap. Choose the pipe and silencer so backpressure stays within the engine datasheet limit; avoid long runs and many bends. Discharge away from the air inlet.
  • Large units usually use residential or critical grade silencers, with a separate exhaust run per unit when running in parallel.

Configuration

Open · Silent · Container

  • Open units for a generator room; silent canopy or silent container for outdoors.
  • A synchronizing panel for parallel operation of several units, including load sharing and N+1 redundancy.
Projects

Generator Projects Around 1500 kVA

Projects from our project list with units of around 1500 kVA.

More project references, 2021–2026

5 projects with units of around 1500 kVA in our 2021–2026 project list. Client names are not shown.

  • Baudouin 1500 kVA

    Hospital

    Malang, East Java · 2026

  • Baudouin 1500 kVA

    Water supply & pumping station

    Makassar, South Sulawesi · 2024

  • Mitsubishi 1500 kVA

    Data center & telecom

    Surabaya, East Java · 2022

  • Cummins 1500 kVA

    Hospital

    Bojonegoro, East Java · 2025

  • Perkins 1500 kVA

    Hospital

    Surabaya, East Java · 2023

FAQ

Frequently Asked Questions

How much does a 1500 kVA generator cost?

The price of a 1500 kVA generator depends on the engine brand, the configuration (open type, silent canopy, silent container), an ATS/AMF or synchronizing panel, installation and commissioning, the delivery location, and the warranty and after-sales service. Use Request a Quote with your requirements and our sales team will send a quotation. What shapes a generator price

How many kW is a 1500 kVA generator?

At the 0.8 power factor commonly used for generators, 1500 kVA equals 1200 kW. The exact kW of each model is on its specification page.

How much diesel does a 1500 kVA generator use?

At 75% load, the 1500 kVA prime generators in our catalogue use about 237–250 L/hr, depending on the engine brand and model. Fuel use at 50% and 100% load is on each model's page.

Should I choose 1500 kVA prime or standby?

Choose a 1500 kVA prime model if the generator is the main power source or runs long hours with a varying load. If you need 1500 kVA only as backup during grid outages, a model with a 1500 kVA standby rating (and a slightly lower prime rating) is usually enough and more economical.

Conductorjasa industrial generator distribution for power projects across Indonesia
By the Numbers

Trusted by Various Companies

Decades of experience and a portfolio of projects across many sectors reflect our commitment to quality.

Our clients

  • Otsuka
  • BCA
  • Santos Jaya Abadi
  • Bank Indonesia
  • Telkom Indonesia
  • Adhi Karya
  • IKEA
  • JW Marriott
  • Spazio
  • Universitas Brawijaya
  • PUPR
  • Siloam Hospitals
  • Djarum
  • Avian Brands
  • PLN
  • Waskita
  • KAI
  • Ciputra World
  • Hero
  • Golden Palace Hotel
  • Institut Teknologi Bandung
  • Universitas Negeri Surabaya
  • Pemerintah Kota Mataram
  • Kievit
  • Gudang Garam
  • Polygon
  • Pertamina Geothermal Energy
  • WIKA
  • INKA
  • Giant
  • Ibis Hotel
  • Universitas Gadjah Mada
  • Universitas Ciputra
  • Pemerintah Kota Surabaya
  • Huawei
  • MNC
  • Kapal Api
  • PGN
  • PP Properti
  • Bulog
  • Transmart
  • Vasa Hotel
  • Westown View
  • Universitas Airlangga
  • Kementerian Sosial
  • National Hospital
Conductorjasa generator assembly workshop in Surabaya
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.