Skip to main content
Generator JERBINDO DJPS-400 WP
Diesel Generator Set | Deutz

JERBINDO DJPS-400 WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO DJPS-400 WP — Open Frame
Generator JERBINDO DJPS-400 WP — Silent
Generator JERBINDO DJPS-400 WP — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
400 kVA
320 kW
Standby Power
440 kVA
352 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
69.3 L/hr

JERBINDO DJPS-400 WP is a diesel generator rated at 400 kVA prime and 440 kVA standby, powered by a water-cooled Deutz BF8M 1015 C engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Hospital
  • Hotel
  • Office Tower

Engine System

Cooling SystemWater Cooled
Engine BrandDeutz
Engine ModelBF8M 1015 C

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement8 V
Cylinders8
Displacement15.9 L
Bore132 mm
Stroke145 mm
GovernorElectronic
Max Engine Power418 kWm
Oil Capacity43 L

Alternator

Brand & ModelStamford HCI 434 F
Power Factor | Voltage0.8 | 400 V

Power Output

Prime Output400 kVA | 320 kW
Standby Output440 kVA | 352 kW
Voltage | Frequency | Speed400 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)2900 x 1500 x 2100 mm4200 x 1600 x 2615 mm
Dry Weight3000 kg3450 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load93.7 L/hr
  • 75% Typical Load69.3 L/hr
  • 50% Light Load46.4 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 69.3 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO DJPS-400 WP best?

This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 400 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 400 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 440 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-400 WP1 Open Type — Open Frame
Generator JERBINDO CJPS C-400 WP1 Open Type — Silent
Generator JERBINDO CJPS C-400 WP1 Open Type — Silent Mobile
JERBINDO

CJPS C-400 WP1

Engine: Cummins QSZ13-G7

Prime
400 kVA
Standby
440 kVA
Alternator
Stamford S4L1D-F41
Cooling
Water Cooled
Fuel @ 75%
73.3 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-400 WP2 Open Type — Open Frame
Generator JERBINDO CJPS C-400 WP2 Open Type — Silent
Generator JERBINDO CJPS C-400 WP2 Open Type — Silent Mobile
JERBINDO

CJPS C-400 WP2

Engine: Cummins NTAA855-G7A

Prime
400 kVA
Standby
440 kVA
Alternator
Stamford S4L1D-F41
Cooling
Water Cooled
Fuel @ 75%
67.8 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO PJPS-400 WP Open Type — Open Frame
Generator JERBINDO PJPS-400 WP Open Type — Silent
Generator JERBINDO PJPS-400 WP Open Type — Silent Mobile
JERBINDO

PJPS-400 WP

Engine: Perkins 2206 C-E13TAG3

Prime
400 kVA
Standby
440 kVA
Alternator
Stamford S4L1D-F41
Cooling
Water Cooled
Fuel @ 75%
65 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-400WP Open Type — Open Frame
Generator JERBINDO CJPS C-400WP Open Type — Silent
JERBINDO

CJPS C-400WP

Engine: Cummins QSG12-G4

Prime
400 kVA
Standby
440 kVA
Alternator
Stamford S4L1D-F41
Cooling
Water Cooled
Fuel @ 75%
60 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.