CJPS C-225 WP
Engine: Cummins 6LTAA8.9G2
- Prime
- 225 kVA
- Standby
- 247.5 kVA
- Alternator
- Stamford UCDI274J
- Cooling
- Water Cooled
- Fuel @ 75%
- 39 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO CJPS O-225 WP is a diesel generator rated at 225 kVA prime and 247.5 kVA standby, powered by a water-cooled Cummins QSL9-G2 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Cummins |
| Engine Model | QSL9-G2 |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 4 in-line |
| Cylinders | 4 |
| Displacement | 8.8 L |
| Bore | 114 mm |
| Stroke | 145 mm |
| Governor | Electronic |
| Max Engine Power | 280 kWm |
| Oil Capacity | 26.5 L |
| Brand & Model | Stamford UCD274J |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 225 kVA | 180 kW |
|---|---|
| Standby Output | 247.5 kVA | 198 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 2500 x 1100 x 1800 mm | 4000 x 1400 x 2300 mm |
| Dry Weight | 2300 kg | 2680 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 225 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 225 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 247.5 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Cummins 6LTAA8.9G2
Open TypeOption: Silent



Engine: Perkins 1506A-E88TAG2
Open TypeOption: Silent



Engine: Perkins 1506A-E88TAG2
Open TypeOption: Silent



Engine: Cummins 6CTAA8.3-G2
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.