Skip to main content
Generator JERBINDO PJPS-225 WP
Diesel Generator Set | Perkins

JERBINDO PJPS-225 WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO PJPS-225 WP — Open Frame
Generator JERBINDO PJPS-225 WP — Silent
Generator JERBINDO PJPS-225 WP — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
225 kVA
180 kW
Standby Power
247.5 kVA
198 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
38 L/hr

JERBINDO PJPS-225 WP is a diesel generator rated at 225 kVA prime and 247.5 kVA standby, powered by a water-cooled Perkins 1506A-E88TAG2 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Hospital
  • Hotel
  • Office Tower

Engine System

Cooling SystemWater Cooled
Engine BrandPerkins
Engine Model1506A-E88TAG2

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement6 in-line
Cylinders6
Displacement8.8 L
Bore112 mm
Stroke149 mm
GovernorMechanical
Max Engine Power224 kWm
Oil Capacity41 L

Alternator

Brand & ModelStamford UCDI274K
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output225 kVA | 180 kW
Standby Output247.5 kVA | 198 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)2800 x 1100 x 1700 mm4000 x 1400 x 2300 mm
Dry Weight1450 kg1650 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load51 L/hr
  • 75% Typical Load38 L/hr
  • 50% Light Load26 L/hr

Tank capacity: 480 L

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 38 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO PJPS-225 WP best?

This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 225 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 225 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 247.5 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-225 WP Open Type — Open Frame
Generator JERBINDO CJPS C-225 WP Open Type — Silent
Generator JERBINDO CJPS C-225 WP Open Type — Silent Mobile
JERBINDO

CJPS C-225 WP

Engine: Cummins 6LTAA8.9G2

Prime
225 kVA
Standby
247.5 kVA
Alternator
Stamford UCDI274J
Cooling
Water Cooled
Fuel @ 75%
39 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS O-225 WP Open Type — Open Frame
Generator JERBINDO CJPS O-225 WP Open Type — Silent
Generator JERBINDO CJPS O-225 WP Open Type — Silent Mobile
JERBINDO

CJPS O-225 WP

Engine: Cummins QSL9-G2

Prime
225 kVA
Standby
247.5 kVA
Alternator
Stamford UCD274J
Cooling
Water Cooled
Fuel @ 75%
46 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO PJPS-230 WP Open Type — Open Frame
Generator JERBINDO PJPS-230 WP Open Type — Silent
Generator JERBINDO PJPS-230 WP Open Type — Silent Mobile
JERBINDO

PJPS-230 WP

Engine: Perkins 1506A-E88TAG2

Prime
230 kVA
Standby
253 kVA
Alternator
Stamford UCDI 274 J
Cooling
Water Cooled
Fuel @ 75%
38 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO PJPS-200 WP Open Type — Open Frame
Generator JERBINDO PJPS-200 WP Open Type — Silent
Generator JERBINDO PJPS-200 WP Open Type — Silent Mobile
JERBINDO

PJPS-200 WP

Engine: Perkins 1106A-70TAG4

Prime
200 kVA
Standby
220 kVA
Alternator
Stamford UCI 274 H
Cooling
Water Cooled
Fuel @ 75%
34.7 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.