Skip to main content
Generator JERBINDO CJPS C-60 WP1
Diesel Generator Set | Cummins

JERBINDO CJPS C-60 WP1

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO CJPS C-60 WP1 — Open Frame
Generator JERBINDO CJPS C-60 WP1 — Silent
Generator JERBINDO CJPS C-60 WP1 — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
60 kVA
48 kW
Standby Power
66 kVA
52.8 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
9.8 L/hr

JERBINDO CJPS C-60 WP1 is a diesel generator rated at 60 kVA prime and 66 kVA standby, powered by a water-cooled Cummins 4BTA3.9-G2 engine with a Stamford alternator. The unit is designed for power needs in clinic, hotel, commercial building, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Clinic
  • Hotel
  • Commercial Building

Engine System

Cooling SystemWater Cooled
Engine BrandCummins
Engine Model4BTA3.9-G2

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement4 in-line
Cylinders4
Displacement3.9 L
Bore102 mm
Stroke120 mm
GovernorElectronic
Max Engine Power50 kWm
Oil Capacity10.9 L

Alternator

Brand & ModelStamford S1L2-Y1
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output60 kVA | 48 kW
Standby Output66 kVA | 52.8 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)1850 x 970 x 1530 mm2450 x 1080 x 1770 mm
Dry Weight1170 kg1490 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load13.1 L/hr
  • 75% Typical Load9.8 L/hr
  • 50% Light Load6.7 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 9.8 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO CJPS C-60 WP1 best?

This unit is designed for clinic, hotel, commercial building. With water-cooled operation and a prime rating of 60 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 60 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 66 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-60 WP2 Open Type — Open Frame
Generator JERBINDO CJPS C-60 WP2 Open Type — Silent
Generator JERBINDO CJPS C-60 WP2 Open Type — Silent Mobile
JERBINDO

CJPS C-60 WP2

Engine: Cummins 4BTA3.9-G11

Prime
60 kVA
Standby
66 kVA
Alternator
Stamford UCI224G
Cooling
Water Cooled
Fuel @ 75%
13 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO DJPS-60 AP Open Type — Open Frame
Generator JERBINDO DJPS-60 AP Open Type — Silent
Generator JERBINDO DJPS-60 AP Open Type — Silent Mobile
JERBINDO

DJPS-60 AP

Engine: Deutz F6L912

Prime
60 kVA
Standby
66 kVA
Alternator
Stamford UCI 224 E
Cooling
Air Cooled
Fuel @ 75%
10.8 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO PJPS-60 WP1 Open Type — Open Frame
Generator JERBINDO PJPS-60 WP1 Open Type — Silent
Generator JERBINDO PJPS-60 WP1 Open Type — Silent Mobile
JERBINDO

PJPS-60 WP1

Engine: Perkins 1103A-33TG2

Prime
60 kVA
Standby
66 kVA
Alternator
Stamford S1L2-Y1
Cooling
Water Cooled
Fuel @ 75%
10.4 L/hr

Open TypeOption: Silent

View Specs
Generator VOLTRAGEN Voltra-60 Silent — Silent
VOLTRAGEN

Voltra-60

Engine: FAW 4DX23-78D

Prime
60 kVA
Standby
66 kVA
Alternator
VOLTRA-60
Cooling
Water Cooled
Fuel @ 75%
12 L/hr

Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.