CJPS C-250 WP1
Engine: Cummins 6LTAA8.9G2
- Prime
- 250 kVA
- Standby
- 275 kVA
- Alternator
- Stamford UCDI 274 K
- Cooling
- Water Cooled
- Fuel @ 75%
- 39 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO CJPS O-250 WP is a diesel generator rated at 250 kVA prime and 275 kVA standby, powered by a water-cooled Cummins QSL9-G3 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Cummins |
| Engine Model | QSL9-G3 |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 4 in-line |
| Cylinders | 4 |
| Displacement | 8.8 L |
| Bore | 114 mm |
| Stroke | 145 mm |
| Governor | Electronic |
| Max Engine Power | 257 kWm |
| Oil Capacity | 26.5 L |
| Brand & Model | Stamford UCD 274 K |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 250 kVA | 200 kW |
|---|---|
| Standby Output | 275 kVA | 220 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 2650 x 1100 x 1800 mm | 4000 x 1400 x 2400 mm |
| Dry Weight | 3100 kg | 3600 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 250 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 250 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 275 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Cummins 6LTAA8.9G2
Open TypeOption: Silent



Engine: Cummins MTA11-G2A
Open TypeOption: Silent



Engine: Cummins QSL8.9-G4
Open TypeOption: Silent



Engine: Cummins NT855-GA
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.