DJPS-45 AP
Engine: Deutz F4L914
- Prime
- 45 kVA
- Standby
- 49.5 kVA
- Alternator
- Stamford UCI 224 D
- Cooling
- Air Cooled
- Fuel @ 75%
- 8 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO CJPS C-43 WP is a diesel generator rated at 43 kVA prime and 47.3 kVA standby, powered by a water-cooled Cummins 4BTA3.9-G2 engine with a Stamford alternator. The unit is designed for power needs in clinic, hotel, commercial building, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Cummins |
| Engine Model | 4BTA3.9-G2 |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 4 in-line |
| Cylinders | 4 |
| Displacement | 3.9 L |
| Bore | 102 mm |
| Stroke | 120 mm |
| Governor | Electronic |
| Max Engine Power | 55 kWm |
| Oil Capacity | 11 L |
| Brand & Model | Stamford S1L2-Y1 |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 43 kVA | 40 kW |
|---|---|
| Standby Output | 47.3 kVA | 44 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 1850 x 970 x 1530 mm | 2600 x 1200 x 1530 mm |
| Dry Weight | 1070 kg | 1390 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
Tank capacity: 100 L
This unit is designed for clinic, hotel, commercial building. With water-cooled operation and a prime rating of 43 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 43 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 47.3 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Deutz F4L914
Open TypeOption: Silent



Engine: Perkins 1103A-33TG1
Open TypeOption: Silent



Engine: Cummins 4BT3.9-G2
Open TypeOption: Silent



Engine: Deutz F4L 912
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.