Skip to main content
Generator JERBINDO PJPS-45 WP1
Diesel Generator Set | Perkins

JERBINDO PJPS-45 WP1

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO PJPS-45 WP1 — Open Frame
Generator JERBINDO PJPS-45 WP1 — Silent
Generator JERBINDO PJPS-45 WP1 — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
45 kVA
36 kW
Standby Power
49.5 kVA
39.6 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
5.6 L/hr

JERBINDO PJPS-45 WP1 is a diesel generator rated at 45 kVA prime and 49.5 kVA standby, powered by a water-cooled Perkins 1103A-33TG1 engine with a Stamford alternator. The unit is designed for power needs in clinic, hotel, commercial building, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Clinic
  • Hotel
  • Commercial Building

Engine System

Cooling SystemWater Cooled
Engine BrandPerkins
Engine Model1103A-33TG1

Engine Specifications

AspirationTurbocharged
Cylinder Arrangement3 in-line
Cylinders3
Displacement3.3 L
Bore105 mm
Stroke127 mm
GovernorMechanical
Max Engine Power46.5 kWm
Oil Capacity8.3 L

Alternator

Brand & ModelStamford S1L2-N1
Power Factor | Voltage0.8 | 400 V

Power Output

Prime Output45 kVA | 36 kW
Standby Output49.5 kVA | 39.6 kW
Voltage | Frequency | Speed400 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)1200 x 900 x 1200 mm2600 x 1200 x 1500 mm
Dry Weight870 kg1131 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load7.2 L/hr
  • 75% Typical Load5.6 L/hr
  • 50% Light Load4.1 L/hr

Tank capacity: 100 L

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 5.6 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO PJPS-45 WP1 best?

This unit is designed for clinic, hotel, commercial building. With water-cooled operation and a prime rating of 45 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 45 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 49.5 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO DJPS-45 AP Open Type — Open Frame
Generator JERBINDO DJPS-45 AP Open Type — Silent
Generator JERBINDO DJPS-45 AP Open Type — Silent Mobile
JERBINDO

DJPS-45 AP

Engine: Deutz F4L914

Prime
45 kVA
Standby
49.5 kVA
Alternator
Stamford UCI 224 D
Cooling
Air Cooled
Fuel @ 75%
8 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-43 WP Open Type — Open Frame
Generator JERBINDO CJPS C-43 WP Open Type — Silent
Generator JERBINDO CJPS C-43 WP Open Type — Silent Mobile
JERBINDO

CJPS C-43 WP

Engine: Cummins 4BTA3.9-G2

Prime
43 kVA
Standby
47.3 kVA
Alternator
Stamford S1L2-Y1
Cooling
Water Cooled
Fuel @ 75%
7.8 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-40 WP Open Type — Open Frame
Generator JERBINDO CJPS C-40 WP Open Type — Silent
Generator JERBINDO CJPS C-40 WP Open Type — Silent Mobile
JERBINDO

CJPS C-40 WP

Engine: Cummins 4BT3.9-G2

Prime
40 kVA
Standby
44 kVA
Alternator
Stamford S1L2-K1
Cooling
Water Cooled
Fuel @ 75%
7.9 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO DJPS-40 AP Open Type — Open Frame
Generator JERBINDO DJPS-40 AP Open Type — Silent
Generator JERBINDO DJPS-40 AP Open Type — Silent Mobile
JERBINDO

DJPS-40 AP

Engine: Deutz F4L 912

Prime
40 kVA
Standby
44 kVA
Alternator
Stamford PI 144 J
Cooling
Air Cooled
Fuel @ 75%
7.3 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.