Skip to main content
Generator JERBINDO DJPS-40 AP
Diesel Generator Set | Deutz

JERBINDO DJPS-40 AP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO DJPS-40 AP — Open Frame
Generator JERBINDO DJPS-40 AP — Silent
Generator JERBINDO DJPS-40 AP — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
40 kVA
32 kW
Standby Power
44 kVA
35.2 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
7.3 L/hr

JERBINDO DJPS-40 AP is a diesel generator rated at 40 kVA prime and 44 kVA standby, powered by a air-cooled Deutz F4L 912 engine with a Stamford alternator. The unit is designed for power needs in clinic, hotel, commercial building, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Clinic
  • Hotel
  • Commercial Building

Engine System

Cooling SystemAir Cooled
Engine BrandDeutz
Engine ModelF4L 912

Engine Specifications

Cylinder Arrangement4-inline
Cylinders4
Displacement4.3 L
Bore103 mm
Stroke132 mm
GovernorMechanical
Max Engine Power38 kWm
Oil Capacity11 L

Alternator

Brand & ModelStamford PI 144 J
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output40 kVA | 32 kW
Standby Output44 kVA | 35.2 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)1800 x 760 x 1250 mm2200 x 1000 x 1500 mm
Dry Weight765 kg950 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load9.7 L/hr
  • 75% Typical Load7.3 L/hr
  • 50% Light Load5.3 L/hr

Unit Highlights

  • Air cooling: simpler installation with no additional water infrastructure
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 7.3 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO DJPS-40 AP best?

This unit is designed for clinic, hotel, commercial building. With air-cooled operation and a prime rating of 40 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 40 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 44 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-40 WP Open Type — Open Frame
Generator JERBINDO CJPS C-40 WP Open Type — Silent
Generator JERBINDO CJPS C-40 WP Open Type — Silent Mobile
JERBINDO

CJPS C-40 WP

Engine: Cummins 4BT3.9-G2

Prime
40 kVA
Standby
44 kVA
Alternator
Stamford S1L2-K1
Cooling
Water Cooled
Fuel @ 75%
7.9 L/hr

Open TypeOption: Silent

View Specs
Generator VOLTRAGEN Voltra-40 Silent — Silent
VOLTRAGEN

Voltra-40

Engine: FAW 4DX21-53D

Prime
40 kVA
Standby
44 kVA
Alternator
VOLTRA-40
Cooling
Water Cooled
Fuel @ 75%
9.5 L/hr

Silent

View Specs
Generator JERBINDO DJPS-40 OP1 Open Type — Open Frame
Generator JERBINDO DJPS-40 OP1 Open Type — Silent
Generator JERBINDO DJPS-40 OP1 Open Type — Silent Mobile
JERBINDO

DJPS-40 OP1

Engine: Deutz BF4L2011

Prime
40 kVA
Standby
44 kVA
Alternator
Stamford PI 144 J
Cooling
Oil Cooled
Fuel @ 75%
7.4 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO DJPS-40 OP2 Open Type — Open Frame
Generator JERBINDO DJPS-40 OP2 Open Type — Silent
Generator JERBINDO DJPS-40 OP2 Open Type — Silent Mobile
JERBINDO

DJPS-40 OP2

Engine: Deutz BF4M2011

Prime
40 kVA
Standby
44 kVA
Alternator
Stamford PI 144 J
Cooling
Oil Cooled
Fuel @ 75%
8.1 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.