Skip to main content
Generator JERBINDO CJPS O-1650 WP
Diesel Generator Set | Cummins

JERBINDO CJPS O-1650 WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO CJPS O-1650 WP — Open Frame
Generator JERBINDO CJPS O-1650 WP — Silent

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
1650 kVA
1320 kW
Standby Power
1815 kVA
1452 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
265 L/hr

JERBINDO CJPS O-1650 WP is a diesel generator rated at 1650 kVA prime and 1815 kVA standby, powered by a water-cooled Cummins QSK50-G7 engine with a Stamford alternator. The unit is designed for power needs in data center, hospital, commercial complex, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Data Center
  • Hospital
  • Commercial Complex

Engine System

Cooling SystemWater Cooled
Engine BrandCummins
Engine ModelQSK50-G7

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement16 V
Cylinders16
Displacement50.3 L
Bore159 mm
Stroke159 mm
GovernorElectronic
Max Engine Power1581 kWm
Oil Capacity235 L

Alternator

Brand & ModelStamford S7L1D-D41
Power Factor | Voltage0.8 | 400 V

Power Output

Prime Output1650 kVA | 1320 kW
Standby Output1815 kVA | 1452 kW
Voltage | Frequency | Speed400 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)6400 x 2260 x 2685 mm12000 x 4000 x 5160 mm
Dry Weight12700 kg14605 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load349 L/hr
  • 75% Typical Load265 L/hr
  • 50% Light Load189 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 265 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO CJPS O-1650 WP best?

This unit is designed for data center, hospital, commercial complex. With water-cooled operation and a prime rating of 1650 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 1650 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 1815 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. A silent container option is also available from 1000 kVA. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO PJPS-1650 WP1 Open Type — Open Frame
Generator JERBINDO PJPS-1650 WP1 Open Type — Silent
JERBINDO

PJPS-1650 WP1

Engine: Perkins 4012-46TAG3A

Prime
1650 kVA
Standby
1815 kVA
Alternator
Stamford S7L1D-D41
Cooling
Water Cooled
Fuel @ 75%
275 L/hr

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO CJPS C-1705 WP Open Type — Open Frame
Generator JERBINDO CJPS C-1705 WP Open Type — Silent
JERBINDO

CJPS C-1705 WP

Engine: Cummins QSK50-G13

Prime
1705 kVA
Standby
1875.5 kVA
Alternator
Stamford S7L1D-E4
Cooling
Water Cooled
Fuel @ 75%
238 L/hr

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO PJPS-1710 WP Open Type — Open Frame
Generator JERBINDO PJPS-1710 WP Open Type — Silent
JERBINDO

PJPS-1710 WP

Engine: Perkins 4012-46TAG3A

Prime
1710 kVA
Standby
1881 kVA
Alternator
Stamford S7L1D-E4
Cooling
Water Cooled
Fuel @ 75%
275 L/hr

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO MJPS-1740 Open Type — Open Frame
Generator JERBINDO MJPS-1740 Open Type — Silent
JERBINDO

MJPS-1740

Engine: Mitsubishi S16R-PTA

Prime
1740 kVA
Standby
1914 kVA
Alternator
Stamford PI 734 E
Cooling
Water Cooled
Fuel @ 75%
260 L/hr

Open TypeOption: SilentOption: Container

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need