Skip to main content
Generator JERBINDO PJPS-1710 WP
Diesel Generator Set | Perkins

JERBINDO PJPS-1710 WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO PJPS-1710 WP — Open Frame
Generator JERBINDO PJPS-1710 WP — Silent

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
1710 kVA
1368 kW
Standby Power
1881 kVA
1504.8 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
275 L/hr

JERBINDO PJPS-1710 WP is a diesel generator rated at 1710 kVA prime and 1881 kVA standby, powered by a water-cooled Perkins 4012-46TAG3A engine with a Stamford alternator. The unit is designed for power needs in data center, hospital, commercial complex, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Data Center
  • Hospital
  • Commercial Complex

Engine System

Cooling SystemWater Cooled
Engine BrandPerkins
Engine Model4012-46TAG3A

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement12 V
Cylinders12
Displacement45.842 L
Bore160 mm
Stroke190 mm
GovernorElectronic
Max Engine Power1643 kWm
Oil Capacity177 L

Alternator

Brand & ModelStamford S7L1D-E4
Power Factor | Voltage0.8 | 400 V

Power Output

Prime Output1710 kVA | 1368 kW
Standby Output1881 kVA | 1504.8 kW
Voltage | Frequency | Speed400 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)5200 x 2150 x 2700 mm7700 x 2800 x 3150 mm
Dry Weight10200 kg11700 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load370 L/hr
  • 75% Typical Load275 L/hr
  • 50% Light Load187 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 275 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO PJPS-1710 WP best?

This unit is designed for data center, hospital, commercial complex. With water-cooled operation and a prime rating of 1710 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 1710 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 1881 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. A silent container option is also available from 1000 kVA. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-1705 WP Open Type — Open Frame
Generator JERBINDO CJPS C-1705 WP Open Type — Silent
JERBINDO

CJPS C-1705 WP

Engine: Cummins QSK50-G13

Prime
1705 kVA
Standby
1875.5 kVA
Alternator
Stamford S7L1D-E4
Cooling
Water Cooled
Fuel @ 75%
238 L/hr

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO MJPS-1740 Open Type — Open Frame
Generator JERBINDO MJPS-1740 Open Type — Silent
JERBINDO

MJPS-1740

Engine: Mitsubishi S16R-PTA

Prime
1740 kVA
Standby
1914 kVA
Alternator
Stamford PI 734 E
Cooling
Water Cooled
Fuel @ 75%
260 L/hr

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO PJPS-1750 WP Open Type — Open Frame
Generator JERBINDO PJPS-1750 WP Open Type — Silent
JERBINDO

PJPS-1750 WP

Engine: Perkins 4012-46TAG3A

Prime
1750 kVA
Standby
1925 kVA
Alternator
Stamford S7L1D-E4
Cooling
Water Cooled
Fuel @ 75%
275 L/hr

Open TypeOption: SilentOption: Container

View Specs
Generator JERBINDO BJPS-1750-WP Open Type — Open Frame
Generator JERBINDO BJPS-1750-WP Open Type — Silent
JERBINDO

BJPS-1750-WP

Engine: Baudouin 16M33G1900/5

Prime
1750 kVA
Standby
1900 kVA
Alternator
Leroy Somer LSA 52.3 S5
Cooling
Water Cooled

Open TypeOption: SilentOption: Container

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.