BJPS-150-WP
Engine: Baudouin 6M11G165/5
- Prime
- 150 kVA
- Standby
- 165 kVA
- Alternator
- Leroy Somer TAL A44 J
- Cooling
- Water Cooled
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO PJPS-150 WP is a diesel generator rated at 150 kVA prime and 165 kVA standby, powered by a water-cooled Perkins 1106A-70TAG2 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Perkins |
| Engine Model | 1106A-70TAG2 |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 6 in-line |
| Cylinders | 6 |
| Displacement | 7.01 L |
| Bore | 105 mm |
| Stroke | 135 mm |
| Governor | Mechanical |
| Max Engine Power | 153 kWm |
| Oil Capacity | 16.5 L |
| Brand & Model | Stamford UCI 274 F |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 150 kVA | 120 kW |
|---|---|
| Standby Output | 165 kVA | 132 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 2600 x 750 x 1570 mm | 3400 x 1200 x 2300 mm |
| Dry Weight | 1416 kg | 1991 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
Tank capacity: 200 L
This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 150 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 150 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 165 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Baudouin 6M11G165/5
Open TypeOption: Silent



Engine: Cummins 6BTAA5.9-G12
Open TypeOption: Silent



Engine: Cummins QSB7-G3
Open TypeOption: Silent



Engine: Deutz BF6M1013EC
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.