DJPS-12.5 OP
Engine: Deutz F2L 2011
- Prime
- 12.5 kVA
- Standby
- 14 kVA
- Alternator
- Stamford PI 044 F
- Cooling
- Oil Cooled
- Fuel @ 75%
- 2.6 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO DJPS-12 OP is a diesel generator rated at 12 kVA prime and 13.2 kVA standby, powered by a oil-cooled Deutz F2M 2011 engine with a Stamford alternator. The unit is designed for power needs in workshop, utility room, small factory, with high operational reliability and optimal fuel efficiency.
| Cooling System | Oil Cooled |
|---|---|
| Engine Brand | Deutz |
| Engine Model | F2M 2011 |
| Cylinder Arrangement | 2-inline |
|---|---|
| Cylinders | 2 |
| Displacement | 1.6 L |
| Bore | 94 mm |
| Stroke | 112 mm |
| Governor | Electrical |
| Max Engine Power | 13 kWm |
| Oil Capacity | 6 L |
| Brand & Model | Stamford PI 044 F |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 12 kVA | 9.6 kW |
|---|---|
| Standby Output | 13.2 kVA | 10.6 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 1200 x 660 x 1050 mm | 1700 x 900 x 1130 mm |
| Dry Weight | 470 kg | 611 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
This unit is designed for workshop, utility room, small factory. With oil-cooled operation and a prime rating of 12 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 12 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 13.2 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Deutz F2L 2011
Open TypeOption: Silent



Engine: Perkins 403A-15G1
Open TypeOption: Silent



Engine: Perkins 403A-1 1G1
Open TypeOption: Silent



Engine: Perkins 403A-15G2
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.