CJPS C-125 WP
Engine: Cummins 6BTAA5.9G2
- Prime
- 125 kVA
- Standby
- 137.5 kVA
- Alternator
- Stamford UCI274E
- Cooling
- Water Cooled
- Fuel @ 75%
- 23 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO DJPS-130 WP is a diesel generator rated at 130 kVA prime and 143 kVA standby, powered by a water-cooled Deutz BF 4M 1013 FC engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Deutz |
| Engine Model | BF 4M 1013 FC |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 4 in-line |
| Cylinders | 4 |
| Displacement | 4.8 L |
| Bore | 108 mm |
| Stroke | 130 mm |
| Governor | Mechanical |
| Max Engine Power | 129 kWm |
| Oil Capacity | 11 L |
| Brand & Model | Stamford UCI 274 E |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 130 kVA | 104 kW |
|---|---|
| Standby Output | 143 kVA | 114.4 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 2200 x 756 x1560 mm | 3600 x1200 x 2300 mm |
| Dry Weight | 1330 kg | 1550 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 130 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 130 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 143 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Cummins 6BTAA5.9G2
Open TypeOption: Silent



Engine: Baudouin 6M11G150/5
Open TypeOption: Silent



Engine: Cummins QSB5-G6
Open TypeOption: Silent



Engine: Perkins 1106A-70TG1
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.