Skip to main content
Generator JERBINDO DJPS-30 OP1
Diesel Generator Set | Deutz

JERBINDO DJPS-30 OP1

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO DJPS-30 OP1 — Open Frame
Generator JERBINDO DJPS-30 OP1 — Silent
Generator JERBINDO DJPS-30 OP1 — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
30 kVA
24 kW
Standby Power
33 kVA
26.4 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
7.4 L/hr

JERBINDO DJPS-30 OP1 is a diesel generator rated at 30 kVA prime and 33 kVA standby, powered by a oil-cooled Deutz BF4L2011 engine with a Stamford alternator. The unit is designed for power needs in workshop, utility room, small factory, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Workshop
  • Utility Room
  • Small Factory

Engine System

Cooling SystemOil Cooled
Engine BrandDeutz
Engine ModelBF4L2011

Engine Specifications

AspirationTurbocharged
Cylinder Arrangement4-inline
Cylinders4
Displacement3.1 L
Bore94 mm
Stroke112 mm
GovernorMechanical
Max Engine Power28 kWm
Oil Capacity10 L

Alternator

Brand & ModelStamford PI 144 G
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output30 kVA | 24 kW
Standby Output33 kVA | 26.4 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)1500 x 760 x 1200 mm2200 x 1100 x 1500 mm
Dry Weight765 kg950 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load10.4 L/hr
  • 75% Typical Load7.4 L/hr
  • 50% Light Load4.9 L/hr

Unit Highlights

  • Oil cooling: a closed system that protects components from environmental contamination
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 7.4 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO DJPS-30 OP1 best?

This unit is designed for workshop, utility room, small factory. With oil-cooled operation and a prime rating of 30 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 30 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 33 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO DJPS-30 OP Open Type — Open Frame
Generator JERBINDO DJPS-30 OP Open Type — Silent
Generator JERBINDO DJPS-30 OP Open Type — Silent Mobile
JERBINDO

DJPS-30 OP

Engine: Deutz F4L2011

Prime
30 kVA
Standby
33 kVA
Alternator
Stamford S0L2-P1
Cooling
Oil Cooled
Fuel @ 75%
7.4 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO DJPS-30 OP2 Open Type — Open Frame
Generator JERBINDO DJPS-30 OP2 Open Type — Silent
Generator JERBINDO DJPS-30 OP2 Open Type — Silent Mobile
JERBINDO

DJPS-30 OP2

Engine: Deutz F4M2011

Prime
30 kVA
Standby
33 kVA
Alternator
Stamford PI 144 G
Cooling
Oil Cooled
Fuel @ 75%
5.7 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-30 WP Open Type — Open Frame
Generator JERBINDO CJPS C-30 WP Open Type — Silent
Generator JERBINDO CJPS C-30 WP Open Type — Silent Mobile
JERBINDO

CJPS C-30 WP

Engine: Cummins 4BT3.9-G1

Prime
30 kVA
Standby
33 kVA
Alternator
Stamford S0L2-P1
Cooling
Water Cooled
Fuel @ 75%
5.4 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-30 WP2 Open Type — Open Frame
Generator JERBINDO CJPS C-30 WP2 Open Type — Silent
Generator JERBINDO CJPS C-30 WP2 Open Type — Silent Mobile
JERBINDO

CJPS C-30 WP2

Engine: Cummins 4BT3.9-G12

Prime
30 kVA
Standby
33 kVA
Alternator
Stamford S0L2-P1
Cooling
Water Cooled
Fuel @ 75%
5.4 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.