Skip to main content
Generator JERBINDO MJPS-750
Diesel Generator Set | Mitsubishi

JERBINDO MJPS-750

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO MJPS-750 — Open Frame
Generator JERBINDO MJPS-750 — Silent
Generator JERBINDO MJPS-750 — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
750 kVA
600 kW
Standby Power
825 kVA
660 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
122 L/hr

JERBINDO MJPS-750 is a diesel generator rated at 750 kVA prime and 825 kVA standby, powered by a water-cooled Mitsubishi S6R2-PTAA-C engine with a Stamford alternator. The unit is designed for power needs in factory, commercial complex, project site, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Factory
  • Commercial Complex
  • Project Site

Engine System

Cooling SystemWater Cooled
Engine BrandMitsubishi
Engine ModelS6R2-PTAA-C

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement6 V
Cylinders6
Displacement29.9 L
Bore170 mm
Stroke220 mm
GovernorElectrical
Max Engine Power710 kWm
Oil Capacity120 L

Alternator

Brand & ModelStamford
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output750 kVA | 600 kW
Standby Output825 kVA | 660 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Dimensions and weight for this unit are prepared per project. Contact us for open type and silent canopy technical drawings.

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load163 L/hr
  • 75% Typical Load122 L/hr
  • 50% Light Load8 1 L/hr

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 122 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO MJPS-750 best?

This unit is designed for factory, commercial complex, project site. With water-cooled operation and a prime rating of 750 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 750 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 825 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO BJPS-750-WP Open Type — Open Frame
Generator JERBINDO BJPS-750-WP Open Type — Silent
Generator JERBINDO BJPS-750-WP Open Type — Silent Mobile
JERBINDO

BJPS-750-WP

Engine: Baudouin 6M33G825/5

Prime
750 kVA
Standby
825 kVA
Alternator
Leroy Somer TAL0A49-B
Cooling
Water Cooled

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-750 WP Open Type — Open Frame
Generator JERBINDO CJPS C-750 WP Open Type — Silent
Generator JERBINDO CJPS C-750 WP Open Type — Silent Mobile
JERBINDO

CJPS C-750 WP

Engine: Cummins KTA38-G2

Prime
750 kVA
Standby
825 kVA
Alternator
Stamford S5L1D-H4
Cooling
Water Cooled
Fuel @ 75%
128 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-750 WP-QSK Open Type — Open Frame
Generator JERBINDO CJPS C-750 WP-QSK Open Type — Silent
Generator JERBINDO CJPS C-750 WP-QSK Open Type — Silent Mobile
JERBINDO

CJPS C-750 WP-QSK

Engine: Cummins QSK19-G20

Prime
750 kVA
Standby
825 kVA
Alternator
Stamford S5L1D-H4
Cooling
Water Cooled
Fuel @ 75%
128 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS O-750 WP Open Type — Open Frame
Generator JERBINDO CJPS O-750 WP Open Type — Silent
Generator JERBINDO CJPS O-750 WP Open Type — Silent Mobile
JERBINDO

CJPS O-750 WP

Engine: Cummins VTA28-G6

Prime
750 kVA
Standby
825 kVA
Alternator
Stamford S5L1D-H4
Cooling
Water Cooled
Fuel @ 75%
131 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.