Prime Power
250 kVA
200 kW
Standby Power
275 kVA
220 kW
RPM / Frequency
1500 rpm / 50 Hz
Fuel Use (75% load)
41 L/hr

JERBINDO PJPS-250 WP is a diesel generator rated at 250 kVA prime and 275 kVA standby, powered by a water-cooled Perkins 1206A-E70TTAG3 engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Hospital
  • Hotel
  • Office Tower

Engine System

Cooling SystemWater Cooled
Engine BrandPerkins
Engine Model1206A-E70TTAG3

Engine Specifications

AspirationTurbocharged, Charge Air Cooled
Cylinder Arrangement6 in-line
Cylinders6
Displacement8.8 L
Bore112 mm
Stroke149 mm
GovernorElectronic
Max Engine Power244 kWm
Oil Capacity41 L

Alternator

Brand & ModelStamford UCDI 274 K
Power Factor | Voltage0.8 | 380 V

Power Output

Prime Output250 kVA | 200 kW
Standby Output275 kVA | 220 kW
Voltage | Frequency | Speed380 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)2800 x 1100 x 1700 mm4000 x 1400 x 2300 mm
Dry Weight2035 kg2380 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Fuel Consumption

  • 100% Full Load56 L/hr
  • 75% Typical Load41 L/hr
  • 50% Light Load29 L/hr

Tank capacity: 300 L

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Stamford alternator: keeps output voltage stable for sensitive equipment
  • Measured fuel use of 41 L/hr at 75% load: predictable operating costs

Frequently Asked Questions

Which operating environments suit the JERBINDO PJPS-250 WP best?

This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 250 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 250 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 275 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-250 WP1 Open Type — Open Frame
Generator JERBINDO CJPS C-250 WP1 Open Type — Silent
Generator JERBINDO CJPS C-250 WP1 Open Type — Silent Mobile
JERBINDO

CJPS C-250 WP1

Engine: Cummins 6LTAA8.9G2

Prime
250 kVA
Standby
275 kVA
Alternator
Stamford UCDI 274 K
Cooling
Water Cooled
Fuel @ 75%
39 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-250 WP3 (CCEC) Open Type — Open Frame
Generator JERBINDO CJPS C-250 WP3 (CCEC) Open Type — Silent
Generator JERBINDO CJPS C-250 WP3 (CCEC) Open Type — Silent Mobile
JERBINDO

CJPS C-250 WP3 (CCEC)

Engine: Cummins MTA11-G2A

Prime
250 kVA
Standby
275 kVA
Alternator
Stamford UCDI 274 K
Cooling
Water Cooled
Fuel @ 75%
42 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-250 WP3 (DCEC) Open Type — Open Frame
Generator JERBINDO CJPS C-250 WP3 (DCEC) Open Type — Silent
Generator JERBINDO CJPS C-250 WP3 (DCEC) Open Type — Silent Mobile
JERBINDO

CJPS C-250 WP3 (DCEC)

Engine: Cummins QSL8.9-G4

Prime
250 kVA
Standby
275 kVA
Alternator
Stamford UCDI 274 K
Cooling
Water Cooled
Fuel @ 75%
41 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS C-250 WP4 Open Type — Open Frame
Generator JERBINDO CJPS C-250 WP4 Open Type — Silent
Generator JERBINDO CJPS C-250 WP4 Open Type — Silent Mobile
JERBINDO

CJPS C-250 WP4

Engine: Cummins NT855-GA

Prime
250 kVA
Standby
275 kVA
Alternator
Stamford UCDI 274 K
Cooling
Water Cooled
Fuel @ 75%
43 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.