Skip to main content
Generator JERBINDO BJPS-200-WP
Diesel Generator Set | Baudouin

JERBINDO BJPS-200-WP

  • Response during business hours
  • Confirmed stock & pricing
  • ISO 9001/14001/45001 & TKDN
Generator JERBINDO BJPS-200-WP — Open Frame
Generator JERBINDO BJPS-200-WP — Silent
Generator JERBINDO BJPS-200-WP — Silent Mobile

Open Frame

*Photo is a product illustration; actual specifications may differ.

Prime Power
200 kVA
160 kW
Standby Power
275 kVA
220 kW
RPM / Frequency
1500 rpm / 50 Hz

JERBINDO BJPS-200-WP is a diesel generator rated at 200 kVA prime and 275 kVA standby, powered by a water-cooled Baudouin 6M16G220/5 engine with a Leroy Somer alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.

Reliable Solution For

  • Hospital
  • Hotel
  • Office Tower

Engine System

Cooling SystemWater Cooled
Engine BrandBaudouin
Engine Model6M16G220/5

Engine Specifications

AspirationTurbocharged, Aftercooled
Cylinder ArrangementInline
Cylinders6
Displacement9.726 L
Bore126 mm
Stroke130 mm
Compression Ratio17:1
Max Engine Power191 kWm

Alternator

Brand & ModelLeroy Somer TALA44M
Power Factor | Voltage0.8 | 400/230 V; 380/220 V

Power Output

Prime Output200 kVA | 160 kW
Standby Output275 kVA | 220 kW
Voltage | Frequency | Speed400/230 V; 380/220 V | 50 Hz | 1500 rpm

Unit Dimensions & Weight

Open Type (standard)Silent Canopy (optional)
Dimensions (L×W×H)2650 x 1200 x 1588 mm3600 x 1400 x 2030 mm
Dry Weight1050 kg1770 kg

Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).

Unit Highlights

  • Water cooling: stable thermal performance in intensive operation in tropical climates
  • 1500 rpm speed, optimal for fuel efficiency under daily operating loads
  • Leroy Somer alternator: keeps output voltage stable for sensitive equipment
  • Reliable for hospital and hotel use with high power availability standards

Frequently Asked Questions

Which operating environments suit the JERBINDO BJPS-200-WP best?

This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 200 kVA, it supports continuous and backup operation in facilities that need high reliability.

When should I use the prime rating and when the standby rating on this unit?

The 200 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 275 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.

Is this unit available as both open frame and silent canopy?

Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.

What should I prepare before requesting a quotation?

Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.

Generator JERBINDO CJPS C-200 WP Open Type — Open Frame
Generator JERBINDO CJPS C-200 WP Open Type — Silent
Generator JERBINDO CJPS C-200 WP Open Type — Silent Mobile
JERBINDO

CJPS C-200 WP

Engine: Cummins 6CTAA8.3-G2

Prime
200 kVA
Standby
220 kVA
Alternator
Stamford UCI274H
Cooling
Water Cooled
Fuel @ 75%
38 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO CJPS O-200 WP Open Type — Open Frame
Generator JERBINDO CJPS O-200 WP Open Type — Silent
Generator JERBINDO CJPS O-200 WP Open Type — Silent Mobile
JERBINDO

CJPS O-200 WP

Engine: Cummins QSB7G5

Prime
200 kVA
Standby
220 kVA
Alternator
Stamford UCI274H
Cooling
Water Cooled
Fuel @ 75%
36 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO DJPS-200 WP Open Type — Open Frame
Generator JERBINDO DJPS-200 WP Open Type — Silent
Generator JERBINDO DJPS-200 WP Open Type — Silent Mobile
JERBINDO

DJPS-200 WP

Engine: Deutz BF6M 1013 FC

Prime
200 kVA
Standby
220 kVA
Alternator
Stamford UCI 274 H
Cooling
Water Cooled
Fuel @ 75%
34.2 L/hr

Open TypeOption: Silent

View Specs
Generator JERBINDO DJPS-200 WP EDT Open Type — Open Frame
Generator JERBINDO DJPS-200 WP EDT Open Type — Silent
Generator JERBINDO DJPS-200 WP EDT Open Type — Silent Mobile
JERBINDO

DJPS-200 WP EDT

Engine: Deutz TCD 2013 L06 4 V DCR

Prime
200 kVA
Standby
220 kVA
Alternator
Stamford HCI 434 D
Cooling
Water Cooled
Fuel @ 75%
48.1 L/hr

Open TypeOption: Silent

View Specs
Need a generator for your business?

Find the Right Industrial Generator Solution

Discuss your power requirements with our sales and service team to get the right products and services.

1977
Experienced since
ISO
9001 · 14001 · 45001
TKDN
Certified products
2
Offices & workshops

Tell Us What You Need

Provide the following information so our team can respond with a solution suited to your requirements.