


DJPS-200 WP EDT
Engine: Deutz TCD 2013 L06 4 V DCR
- Prime
- 200 kVA
- Standby
- 220 kVA
- Alternator
- Stamford HCI 434 D
- Cooling
- Water Cooled
- Fuel @ 75%
- 48.1 L/hr
Open TypeOption: Silent




Open Frame
*Photo is a product illustration; actual specifications may differ.
JERBINDO DJPS-200 WP is a diesel generator rated at 200 kVA prime and 220 kVA standby, powered by a water-cooled Deutz BF6M 1013 FC engine with a Stamford alternator. The unit is designed for power needs in hospital, hotel, office tower, with high operational reliability and optimal fuel efficiency.
| Cooling System | Water Cooled |
|---|---|
| Engine Brand | Deutz |
| Engine Model | BF6M 1013 FC |
| Aspiration | Turbocharged, Charge Air Cooled |
|---|---|
| Cylinder Arrangement | 6 in-line |
| Cylinders | 6 |
| Displacement | 7.2 L |
| Bore | 108 mm |
| Stroke | 130 mm |
| Governor | Electronic |
| Max Engine Power | 201 kWm |
| Oil Capacity | 20 L |
| Brand & Model | Stamford UCI 274 H |
|---|---|
| Power Factor | Voltage | 0.8 | 380 V |
| Prime Output | 200 kVA | 160 kW |
|---|---|
| Standby Output | 220 kVA | 176 kW |
| Voltage | Frequency | Speed | 380 V | 50 Hz | 1500 rpm |
| Open Type (standard) | Silent Canopy (optional) | |
|---|---|---|
| Dimensions (L×W×H) | 2600 x 1000 x 1650 mm | 3600 x 1400 x 2400 mm |
| Dry Weight | 2075 kg | 2400 kg |
Units ship as open type as standard. Silent canopy dimensions are indicative and may change with the canopy specification (noise level, fuel tank capacity, service access).
This unit is designed for hospital, hotel, office tower. With water-cooled operation and a prime rating of 200 kVA, it supports continuous and backup operation in facilities that need high reliability.
The 200 kVA prime rating applies when the generator is the main power source under varying loads, for example at sites without a stable grid supply. The 220 kVA standby rating is for backup during outages, with use limited to no more than 10% of total annual operating hours.
Yes. JERBINDO units come as an open frame for enclosed engine rooms and with a silent canopy for areas that need lower noise. Dimensions and weight differ by configuration; state your preference when requesting a quotation.
Prepare your estimated total load in kW or kVA, the operating type (prime or standby), the installation location, your enclosure preference (open or silent), any ATS or AMF panel needs, and your target operating date. This helps our team recommend the right unit and price.



Engine: Deutz TCD 2013 L06 4 V DCR
Open TypeOption: Silent



Engine: Baudouin 6M16G220/5
Open TypeOption: Silent



Engine: Cummins 6CTAA8.3-G2
Open TypeOption: Silent



Engine: Cummins QSB7G5
Open TypeOption: Silent

Discuss your power requirements with our sales and service team to get the right products and services.